background image

 

- 5 - 

4.2.

 

Mounting Procedure 

1)

 

Use the cleansing tissue (provided) to clean the location where the Surface Microphone 
will be mounted. (Alternatively, clean the surface with isopropanol or cleaning benzene.) 

 

2)

 

To attach the Surface Microphone using the double-sided adhesive pad (see Figure 6)
peel off the protective paper on one side of the pad to expose its adhesive surface, apply 
firmly to the underside of the microphone, then peel off the protective paper on the other 
side of the pad to expose the other adhesive surface, and press it onto the clean surface. 

 

 

Figure 6: Double-sided adhesive pad 

 

NOTE: If the Surface Microphone will be mounted in a location where no air movement 
is expected, the pad can be trimmed beforehand to fit the microphone if desired. If the 
Microphone will be mounted in moving air and will thus require use of the Fairing, center 
the microphone on the pad to ensure adhesion of the Fairing. 

 

3)

 

When the Surface Microphone will be mounted in a location where air movement is 
expected, attach the Fairing: align the Fairing’s slot with the Microphone’s cable and 
press the Fairing down over the microphone and onto the exposed adhesive surface of the 
double-sided adhesive pad, smoothing out the Fairing as necessary. See Figure 7. 

 

 

Figure 7: Fairing installed over Surface Microphone 

 

Summary of Contents for 130B40

Page 1: ...MICROPHONE Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E m...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...ncerning the Microphone or its application feel free to call a factory Application Engineer at 716 684 0001 or your local dedicated PCB Sales Engineer 2 0 Product Description The PCB 130B series of Su...

Page 7: ...or adhesive or flush mounting Additionally the mesh of the microphone s protective grid repels water Figure 2 Typical pressure frequency response curve of Series 130B Series Surface Microphones 3 0 Po...

Page 8: ...lation and Operation 4 1 Mounting Methods Consider the expected air flow across the surface on which the Surface Microphone will be mounted to determine the best way to secure the microphone to the su...

Page 9: ...to its mounting surface Figure 5 One sided Adhesive Pad securing the Surface Microphone and Fairing in place Moderate to heavy air flow Microphone Top single sided adhesive pad Base double sided adhes...

Page 10: ...urface Figure 6 Double sided adhesive pad NOTE If the Surface Microphone will be mounted in a location where no air movement is expected the pad can be trimmed beforehand to fit the microphone if desi...

Page 11: ...The microphone is checked against a test and measurement working standard microphone and must meet specifications before it can be shipped An example of the result of one of the tests is shown above...

Page 12: ...nt Press down slightly to ensure a seal and to minimize outside noise then perform the calibration using the instructions provided in the calibrator s manual 6 0 Service See the supplemental sheet con...

Page 13: ...t 1 5 m Cable Termination 10 32 Coaxial Plug 10 32 Coaxial Plug Size Diameter Without fairing 0 52 in 13 2 mm Size Diameter With fairing 1 62 in 41 0 mm Size Height 0 126 in 3 20 mm Weight 0 3 oz 7 gm...

Page 14: ......

Reviews: