Manual 21354 Rev E 
ECN 50523 

 

 

 

Repair and Maintenance 

 

 

PCB guarantees Total Customer Satisfaction through its 

“Lifetime  Warranty  Plus”  on all  Platinum  Stock  Products 

sold by PCB and through its limited warranties on all other 
PCB  Stock,  Standard  and  Special  products.  Due  to  the 
sophisticated  nature  of  our  sensors  and  associated 
instrumentation, 

field  servicing  and  repair  is  not 

recommended  and,  if  attempted,  will  void  the  factory 
warranty

 
Beyond  routine  calibration  and  battery  replacements 
where  applicable,  our  products  require  no  user 
maintenance.  Clean  electrical  connectors,  housings,  and 
mounting surfaces with solutions and techniques that will 
not  harm  the  material  of  construction.  Observe  caution 
when using liquids near devices that are not hermetically 
sealed.  Such  devices  should  only  be  wiped  with  a 
dampened cloth

never saturated or submerged.  

 

In the event that equipment becomes damaged or ceases 
to operate, our Application Engineers are here to support 
your  troubleshooting  efforts  24  hours  a  day,  7  days  a 
week. Call or email with model and serial number as well 
as a brief description of the problem. 

 

Calibration 

 

 

Routine 

calibration 

of 

sensors 

and 

associated 

instrumentation  is  necessary  to  maintain  measurement 
accuracy. We recommend calibrating on an annual basis, 
after  exposure  to  any  extreme  environmental  influence, 
or prior to any critical test.  

 

PCB Piezotronics is an ISO-9001 certified company whose 
calibration  services  are  accredited  by  A2LA  to  ISO/IEC 
17025,  with  full  traceability  to  SI  through  N.I.S.T.  In 
addition to our standard calibration services, we also offer 
specialized  tests,  including:  sensitivity  at  elevated  or 
cryogenic  temperatures,  phase  response,  extended  high 
or low frequency response, extended range, leak testing, 
hydrostatic  pressure  testing,  and  others.  For  more 
information,  contact  your  local  PCB  Piezotronics 
distributor,  sales  representative,  or  factory  customer 
service representative.  

 

Returning Equipment 

 

If  factory  repair  is  required,  our  representatives  will 
provide you with a Return Material Authorization (RMA) 
number, which we use to reference any information you 
have  already  provided  and  expedite  the  repair  process. 
This number should be clearly marked on the outside of 
all  returned  package(s)  and  on  any  packing  list(s) 
accompanying the shipment.  

 

Contact Information 

 

 

PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840 
24-hour SensorLine: (716) 684-0001 
General inquiries

[email protected]

 

Repair inquiries

[email protected]

  

 

For a complete list of distributors, global offices and sales 
representatives, visit our website, 

www.pcb.com

 

 

Safety Considerations

 

 

This  product  is  intended  for  use  by  qualified  personnel 
who  recognize  shock  hazards  and  are  familiar  with  the 
precautions required to avoid injury. While our equipment 
is  designed  with  user  safety  in  mind,  the  protection 
provided by the equipment may be impaired if equipment 
is used in a manner not specified by this manual.  

 

Discontinue use and contact our 24-Hour Sensorline if: 

 

 

Assistance is needed to safely operate equipment 

 

Damage is visible or suspected 

 

Equipment fails or malfunctions 

 

For  complete  equipment  ratings,  refer  to  the  enclosed 
specification sheet for your product. 

 

Definition of Terms and Symbols 

 

 

The following symbols may be used in this manual: 

 

 

DANGER 

Indicates an immediate hazardous 
situation, which, if not avoided, may 
result in death or serious injury.

 

 

Summary of Contents for 130A25

Page 1: ...EAMPLIFIER 10 32 CONNECTOR TEDS Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 716 684 0001 24 hour SensorLine 716 684 0...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...oustic mode analysis near field acoustic holography or sound intensity measurments To ensure the best performance from your 130 series microphone follow the installation and operating procedures in th...

Page 7: ...g distances with negligible signal loss 3 0 Powering All ICP powered microphones require constant current excitation for proper operation For this reason use only PCB constant current signal condition...

Page 8: ...he end of the housing Sharp edged tools can be used to aid in cover removal but it is important to keep the tool at a shallow angle DO NOT make contact with the microphone s delicate diaphragm right h...

Page 9: ...ce with ISO 9001 ISO 10012 1 and ANSI NCSL Z540 3 4 Due to state of the art limitations 4 1 calibration ratios are not possible on pressure measurement standards microphones and acoustic calibrators C...

Page 10: ...e with ISO 9001 ISO 10012 1 and ANSI NCSL Z540 3 4 Due to state of the art limitations 4 1 calibration ratios are not possible on pressure measurement standards microphones and acoustic calibrators Ca...

Page 11: ...ibration is performed in compliance with ISO 9001 ISO 10012 1 and ANSI NCSL Z540 3 4 Due to state of the art limitations 4 1 calibration ratios are not possible on pressure measurement standards micro...

Page 12: ...ver the microphone output may be affected by harsh environments such as moisture dirt mechanical shock or other unusual conditions This may manifest itself in a number of ways ranging from a loss in f...

Page 13: ...828 8840 ISO 9001 CERTIFIED AS9100 CERTIFIED In the interest of constant product improvement specifications are subject to change without notice Copyright PCB Group Inc 2016 PCB and ICP are registered...

Page 14: ...7 dB 1 Electrical Excitation Voltage 18 to30 VDC 18 to30 VDC Constant Current Excitation 2 to20 mA 2 to20 mA Output Bias Voltage 5 5 to14 VDC 5 5 to14 VDC Output Impedance 150 Ohm 150 Ohm Physical Ho...

Page 15: ...003 005 FILLETS AND RADII 0 07 0 13 OUTLINE DRAWING 72402 1 OF 1 5X MODEL 130A25 ICP MICROPHONE DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JJF 3 23 20 JJF 3 23 20 MJN 3 23 20 72402 PCB Piezotronic...

Reviews: