background image

 
 
 
 
 
 
 
 
 
 
 

DOCUMENT NUMBER: 21354 
DOCUMENT REVISION: 

D

 

ECN: 46162 

 

Component Name 

Hazardous Substances 

Lead 
(Pb) 

Mercury 
(Hg) 

Cadmium 
(Cd) 

Chromium VI 
Compounds 
(Cr(VI)) 

Polybrominated 
Biphenyls 
(PBB) 

Polybrominated 
Diphenyl 
Ethers (PBDE) 

Housing 

PCB Board 

Electrical 
Connectors 

Piezoelectric 
Crystals 

Epoxy 

Teflon 

Electronics 

Thick Film 
Substrate 

Wires 

Cables 

Plastic 

Solder 

Copper Alloy/Brass 

This table is prepared in accordance with the provisions of SJ/T 11364. 

O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit 
requirement of GB/T 26572. 

X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above 
the limit requirement of GB/T 26572. 
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU. 

Summary of Contents for 113B26

Page 1: ... Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail info pcb com Web www pcb com ...

Page 2: ...ity regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme shock load or other environmental influence or prior to any critical test PCB Piezotronics maintains an ISO 9001 certified metrology laboratory and offers calibration services which are accredited by A...

Page 3: ...urchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers should direct all inquiries to their local distributor or sales office A complete list of distributors and offices can be found at www pcb com Customers within the United States may contact their local s...

Page 4: ... O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Page 5: ...te O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at le...

Page 6: ... shows the components of the basic ICP probe i e the piezoelectric element and the ICP source follower amplifier These components are joined together as an inseparable sealed assembly at the factory Disassembly should not be attempted in the field Series 113B2x are in a probe configuration and are installed with a hollow clamp nut with 5 16 24 external threads The housing of these models is at ele...

Page 7: ...ial in many cases One or more layers may be used across the end of diaphragm and adaptor A silicone rubber coating approximately 010 thick has also been proven effective in many applications General Electric RTV type 106 is recommended Apply the rubber coating to the surface of the diaphragm and allow it to cure in accordance with the manufacturer s instructions If you have ordered the CA option a...

Page 8: ...s are also features of these sensors As mentioned previously the diaphragm must be flush mounted to fully realize the high frequency response capabilities of this series 8 0 CALIBRATION Piezoelectric sensors are dynamic devices but static calibration means can be employed if discharge time constants are sufficiently long Generally static methods are not employed below several hundred seconds time ...

Page 9: ......

Page 10: ......

Reviews: