list(s)  accompanying  the  shipment.  A 
detailed  account  of  the  nature  of  the 
problem(s)  being  experienced  with  the 
equipment  should  also  be  included 
inside  the  package(s)  containing  any 
returned materials.   
 
A  Purchase  Order,  included  with  the 
returned  materials,  will  expedite  the 
turn-around  of  serviced  equipment.  It  is 
recommended  to  include  authorization 
on  the  Purchase  Order  for  PCB  to 
proceed  with  any  repairs,  as  long  as 
they  do  not  exceed  50%  of  the 
replacement  cost  of  the  returned 
item(s).  PCB  will  provide  a  price 
quotation 

or 

replacement 

recommendation  for  any  item  whose 
repair  costs  would  exceed  50%  of 
replacement cost, or any item that is not 
economically  feasible  to  repair.  For 
routine 

calibration 

services, 

the 

Purchase 

Order 

should 

include 

authorization  to  proceed  and  return  at 
current  pricing,  which  can  be  obtained 
from 

factory 

customer 

service 

representative.   
 

Contact  Information 

–  International 

customers  should  direct  all  inquiries  to 
their  local  distributor  or  sales  office.  A 

complete  list  of  distributors  and  offices 
can 

be 

found 

at 

www.pcb.com. 

Customers within the United States may 
contact  their  local  sales  representative 
or 

factory 

customer 

service 

representative.  A  complete  list  of  sales 
representatives 

can 

be 

found 

at 

www.pcb.com. 

Toll-free 

telephone 

numbers  for  a  factory  customer  service 
representative, 

in 

the 

division 

responsible  for  this  product,  can  be 
found on the title page at the front of this 
manual.  Our  ship  to  address  and 
general contact numbers are:   
 
PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840  
24-hour SensorLine

SM

: (716) 684-0001  

Website: www.pcb.com 

E-mail: [email protected]  
 
 
 
 
 
 
 
 

Summary of Contents for 113B26

Page 1: ... Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail info pcb com Web www pcb com ...

Page 2: ...ity regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme shock load or other environmental influence or prior to any critical test PCB Piezotronics maintains an ISO 9001 certified metrology laboratory and offers calibration services which are accredited by A...

Page 3: ...urchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers should direct all inquiries to their local distributor or sales office A complete list of distributors and offices can be found at www pcb com Customers within the United States may contact their local s...

Page 4: ... O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Page 5: ...te O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at le...

Page 6: ... shows the components of the basic ICP probe i e the piezoelectric element and the ICP source follower amplifier These components are joined together as an inseparable sealed assembly at the factory Disassembly should not be attempted in the field Series 113B2x are in a probe configuration and are installed with a hollow clamp nut with 5 16 24 external threads The housing of these models is at ele...

Page 7: ...ial in many cases One or more layers may be used across the end of diaphragm and adaptor A silicone rubber coating approximately 010 thick has also been proven effective in many applications General Electric RTV type 106 is recommended Apply the rubber coating to the surface of the diaphragm and allow it to cure in accordance with the manufacturer s instructions If you have ordered the CA option a...

Page 8: ...s are also features of these sensors As mentioned previously the diaphragm must be flush mounted to fully realize the high frequency response capabilities of this series 8 0 CALIBRATION Piezoelectric sensors are dynamic devices but static calibration means can be employed if discharge time constants are sufficiently long Generally static methods are not employed below several hundred seconds time ...

Page 9: ......

Page 10: ......

Reviews: