Jumper JP4: Clear CMOS Memory
Use this jumper to clear the contents of the CMOS memory. You
may need to clear the CMOS memory if the settings in the setup
utility are incorrect and prevent your mainboard from operating. To
clear the CMOS memory, disconnect all the power cables from the
mainboard and then move the jumper cap into the CLEAR setting
for a few seconds.
Function
Jumper Setting
Normal Operation
Short Pins 2-3
Clear CMOS Memory
Short Pins 1-2
Jumper JP8: DIMM Voltage Selector
This jumper has two columns of three pins. Set the two jumper
caps on the pins 1-2 to select a voltage of 5V volts for the memory
module DIMM slots. Set the two jumper caps to pins 2-3 to select a
voltage of 3.3V for the DIMM slots.
Function
Left Column Setting Right Column Setting
5V DIMM
Short Pins 1-2
Short Pins 1-2
3.3V DIMM Short Pins 2-3
Short Pins 2-3
Install the Mainboard
Install the mainboard into the system chassis. This mainboard is
baby AT-sized and the I/O ports are provided on extension
brackets. In addition the mainboard can operate using an AT power
supply unit or an ATX power supply unit. This means that you
have a wide choice of cases that can be used by this mainboard.
Install the mainboard into the unit case. Follow the instructions
provided by the case manufacturer using the screws and mounting
points provided in the chassis.