BEFORE YOU CALL FOR SERVICE, CHECK FOR SEVERAL
EASILY-SOLVED PROBLEMS

If insufficient heating or cooling is suspected:

(

) Check for sufficient airflow. Check the air filter for dirt.

Check for blocked return-air or supply-air grilles. Be sure they
are open and unobstructed. If these checks do not reveal the
cause, call your servicing dealer.

If your unit is not operating at all, check the following list for
easy solutions:

(

) Check to be sure that your thermostat temperature se-

lector is set above the indoor temperature during the heating
season, or below the indoor temperature during the cooling
season. Be sure the system switch is in the proper HEAT or
COOL position and not in the OFF position.

(

) Is the electrical supply switch ON? Are any fuses blown,

or has the circuit breaker tripped?

(

) During the heating season, check the external manual

shutoff valve. Is this lever parallel with the pipe, indicating
that the valve is open? Or is the lever at a right angle,
indicating that the valve is closed? If closed, has the gas been
shut off for safety reasons? Otherwise, you may open the valve
and follow the start-up procedures listed in this manual.

NOTE: Before proceeding with the next check, turn OFF the
gas supply, then the electrical power supply to the unit. Re-
move the control access door.

(

) During the heating season, check the control dial on the

internal gas valve. Is it in the ON position? If it is not, be
sure it was not turned off for the purpose of safety. If no safety
hazards exist, follow the start-up procedures in this manual.

(

) If your unit still fails to operate, call your servicing dealer

for troubleshooting and repairs. Specify the model and serial
numbers of your unit. (Record them in this manual in the
space provided.) If the dealer knows exactly which unit you
have, he may be able to offer suggestions over the phone, or
save valuable time through knowledgeable preparation for the
service call.

IN CASE OF TROUBLE

If after performing the above and unit performance is still
unsatisfactory, shut off the unit and call your dealer.

Dealer’s Name

Telephone

Unit Model

Unit Serial Number

—7—

Summary of Contents for PY1P

Page 1: ...r the gas supplier FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supp...

Page 2: ...If the burners do not light within 15 minutes of the initial call for heat there is a lockout Step 11 Set the temperature selector on room thermostat to desired setting WARNING 1 If the main burners f...

Page 3: ...r replace with new one When installing the new filter s note the direction of the air flow arrows on the filter frame If you have difficulty in locating your air filter s or if you have questions conc...

Page 4: ...STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 STEP 9 STEP 10 Fig 3 To Light Unit 4...

Page 5: ...STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 Fig 4 To Shut Unit Off 5...

Page 6: ...r serious personal injury may result Watch the burner flame to see if it is bright blue If you observe a suspected malfunction or if the burner flames are not bright blue call your dealer 6 Replace bu...

Page 7: ...ight angle indicating that the valve is closed If closed has the gas been shut off for safety reasons Otherwise you may open the valve and follow the start up procedures listed in this manual NOTE Bef...

Page 8: ......

Page 9: ...9...

Page 10: ......

Page 11: ...ed to be free from defects in material and workmanship under normal use and maintenance for a period of one year from the date of original installation whether or not actual use begins on that date A...

Page 12: ...Copyright 1998 Payne Heating Cooling CATALOG NO 53PY 1P4...

Reviews: