Your combination heating/cooling unit is equipped with an
automatic direct spark ignition and power combustion blower.

WARNING:

Do not attempt to light by hand; per-

sonal injury may result.

TO LIGHT UNIT

DANGER:

1. Do not turn off the electrical power to unit without

first turning off the gas supply.

2. Before attempting to start the gas heating section,

familiarize yourself with all the procedures that must
be followed.

If you do not follow these instructions exactly, a fire or
explosion may result, causing property damage, injury,
or loss of life.

Refer to Fig. 1. See Fig. 2 for location of gas valve. Refer to
Fig. 3 while proceeding with the following steps.

Step 1

Set the temperature selector on room thermostat to the low-
est temperature setting and set system switch to HEAT.

Step 2

Close the external manual shutoff valve.

Step 3

Turn off the electrical supply to the unit.

Step 4

Remove the burner access panel with a

5

16

-in. nut driver.

Step 5

Turn the control dial on the internal gas valve counterclock-

wise

to the OFF position and wait 5 minutes.

Step 6

Turn the control dial on the internal gas valve clock-

wise

to the ON position.

Step 7

Replace the burner access panel.

Step 8

Turn on the electrical supply to unit.

Step 9

Open the external manual shutoff valve.

Step 10

Set the temperature selector on room thermostat slightly above
room temperature to start unit. The induced-draft combustion-
air fan will start. Main gas valve will open and main burners
should ignite within 5 seconds. If the burner does not light
within 5 seconds, the ignition module will go into a Retry mode
after a period of approximately 22 seconds (following the
5-second ignition period).

If the burners do not light within 15 minutes of the initial
call for heat, there is a lockout.

Step 11

Set the temperature selector on room thermostat to desired
setting.

WARNING:

1. If the main burners fail to light, or the blower fails

to start, shut down gas heating section and call your
dealer for service.

2. Never attempt to manually light the main burners

on unit with a match, lighter, or any other flame. If
the electric sparking device fails to light the main
burners, refer to the following shutdown proce-
dures, then call your dealer as soon as possible.

Failure to follow these requirements could result in
serious personal injury.

TO SHUT UNIT OFF

WARNING:

Do not turn off the electrical power to unit

without first turning off the gas supply.

Failure to follow these procedures can result in serious
fire or personal injury.

NOTE:

If unit is being shut down because the heating sea-

son has ended, make sure to turn on power to cooling
system.

If unit is being shut down because of a malfunction, call your
dealer as soon as possible.

Should overheating occur or the gas supply fail to shut off,
shut off the manual gas valve to the unit before shutting off
the electrical supply.

Do not use this unit if any part has been under water. Im-
mediately call a qualified service technician to inspect the unit
and to replace any part of the control system and any gas
control which has been under water.

Refer to Fig. 4 while proceeding with the following steps.

Step 1

Set the temperature selector on room thermostat to lowest
temperature setting and set system switch to OFF.

Step 2

Close the external manual shutoff valve.

Step 3

Turn off the electrical power supply to the unit.

Step 4

Remove the burner access panel.

Step 5

Turn the control dial on the internal gas valve counterclock-

wise

to the OFF position.

BURNER
ACCESS
PANEL

Fig. 1 — Gas Heating/Electric Cooling Unit

—2—

Summary of Contents for PY1P

Page 1: ...r the gas supplier FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supp...

Page 2: ...If the burners do not light within 15 minutes of the initial call for heat there is a lockout Step 11 Set the temperature selector on room thermostat to desired setting WARNING 1 If the main burners f...

Page 3: ...r replace with new one When installing the new filter s note the direction of the air flow arrows on the filter frame If you have difficulty in locating your air filter s or if you have questions conc...

Page 4: ...STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 STEP 9 STEP 10 Fig 3 To Light Unit 4...

Page 5: ...STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 Fig 4 To Shut Unit Off 5...

Page 6: ...r serious personal injury may result Watch the burner flame to see if it is bright blue If you observe a suspected malfunction or if the burner flames are not bright blue call your dealer 6 Replace bu...

Page 7: ...ight angle indicating that the valve is closed If closed has the gas been shut off for safety reasons Otherwise you may open the valve and follow the start up procedures listed in this manual NOTE Bef...

Page 8: ......

Page 9: ...9...

Page 10: ......

Page 11: ...ed to be free from defects in material and workmanship under normal use and maintenance for a period of one year from the date of original installation whether or not actual use begins on that date A...

Page 12: ...Copyright 1998 Payne Heating Cooling CATALOG NO 53PY 1P4...

Reviews: