Recommended Filter Sizes

Nominal Air Flow

Cubic Feet

per Minute (CFM)

Recommended Filter Sizes

Nominal Size (inches/mm)

Disposable Filters

Cleanable Filters

800--900

20 x 25 (508.0 x 635.0) (1 Req.)

14 x 25 (355.6 x 635.0) (1 Req.)

1100--1300

14 x 25 (355.6 x 635.0) (2 Req.)

14 x 25 (355.6 x 635.0) (1 Req.)

1300--1500

16 x 18 (406.4 x 457.2) (2 Req.)

16 x 18 (406.4 x 457.2) (1 Req.)

1500--1700

20 x 25 (508.0 x 635.0) (2 Req.)

20 x 25 (508.0 x 635.0) (1 Req.)

1900--2100

20 x 30 (508.0 x 762.0) (2 Req.)

20 x 25 (508.0 x 635.0) (1 Req.)

2300--2500

20 x 30 (508.0 x 762.0) (2 Req.)

24 x 30 (609.6 x 762.0) (1 Req.)

Table 1 – Recommended Filter Sizes

PG

9M

TA

V

Summary of Contents for PG9MTAV

Page 1: ...rvice agency should be contacted to inspect the furnace and to replace all gas controls control system parts electrical parts that have been wet or the furnace if deemed necessary CERTIFIED As an ENERGY STAR Partner Payne Heating Cooling Systems has determined that this product meets the ENERGY STAR guidelines for energy efficiency SAFETY CONSIDERATIONS Recognize safety information This is the saf...

Page 2: ...bilize 5 On appliances with a draft hood check for spillage by holding a lighted match 2 50 8mm from the draft hood opening Reference Fig 1 which shows a water heater draft hood Typical Gas Water Heater Draft Hood Vent Pipe Match A07688 Fig 1 Water Heater Draft Hood a Match flame pulls toward draft hood This indicates no spillage and that appliance is getting enough air for combustion Return exhau...

Page 3: ...ave a Fan Switch with AUTO and ON settings On AUTO the Circulating Air Blower will cycle on off with the furnace on the heating speed unless a call for cooling is initiated Blower speed will correspond to the mode of operation of the furnace If the Fan Switch is positioned to ON the blower will run continuously In addition some thermostats are programmable with multiple set backs The set backs can...

Page 4: ...doors 8 Turn ON all electrical power to the furnace 9 Set the thermostat to the desired temperature and the System Select Switch to HEAT The furnace will activate an igniter which lights the main burners Turning Off The Furnace Set the thermostat to the lowest temperature setting or set System Select Switch to OFF if so equipped Should overheating occur or the gas control valve fail to shut off sh...

Page 5: ...ned or replaced as required There are many types of filters that are commonly used Washable filters constructed of aluminum mesh foam or reinforced fibers may be cleaned by soaking in mild detergent and rinsing with water The fiberglass disposable type should be REPLACED before it becomes clogged Other filter types should be serviced in accordance with the manufacturer s recommendations Remember t...

Page 6: ...nace External Filter Rack A plastic end cap is inserted in the filter rack after the filter is installed The end cap keeps air from escaping around the open end of the filter rack See Fig 4 for removal of filter Filter racks attached to the furnace are made so the filter simply slides out one end for removal 1 Turn OFF electric power to furnace 2 Remove the end cap from the filter rack 3 Slide the...

Page 7: ...x 25 355 6 x 635 0 1 Req 1100 1300 14 x 25 355 6 x 635 0 2 Req 14 x 25 355 6 x 635 0 1 Req 1300 1500 16 x 18 406 4 x 457 2 2 Req 16 x 18 406 4 x 457 2 1 Req 1500 1700 20 x 25 508 0 x 635 0 2 Req 20 x 25 508 0 x 635 0 1 Req 1900 2100 20 x 30 508 0 x 762 0 2 Req 20 x 25 508 0 x 635 0 1 Req 2300 2500 20 x 30 508 0 x 762 0 2 Req 24 x 30 609 6 x 762 0 1 Req Table 1 Recommended Filter Sizes PG9MTAV ...