EXAMPLE:
Btu heating input = Btu/cu ft X cu ft/hr
Heating value of gas = 1070 Btu/cu ft
Time for 1 revolution of 2 cu ft dial = 72 sec
Gas rate = 100 X 1070 = 107,000 Btuh

(8.) Measured gas input should not exceed gas input on

unit rating plate.

(9.) Proceed to item c to adjust manifold pressure.

c. Adjust gas input.

(1.) Remove regulator adjustment seal cap. (See Fig.

11.)

(2.) Turn adjusting screw counterclockwise to decrease

input. Turn screw clockwise to increase input. DO
NOT set manifold pressure less than 3.2-in. wc or
more than 3.8-in. wc for natural gas. Make any
major adjustments by changing main burner ori-
fices.

(3.) When correct input is obtained, replace regulator

seal cap. Main burner flame should be clear blue,
almost transparent. (See Fig. 12.)

d. High altitude—In the United States gas input on rating

plate is for altitudes up to 2000 ft. Ratings for altitudes
over 2000 ft must be 4 percent less for each 1000 ft
above sea level. To obtain the adjusted altitude rating,
adjust the manifold pressure (see item c) and replace the
main burner orifices as needed. Refer to National Fuel
Gas Code Appendix F, Table F-4 for proper orifice
sizing at high altitudes.

e. Canadian installations only—The Canadian ratings are

approved for altitudes up to 2000 ft for natural and
propane gases. High-altitude ratings are from 2000 ft to
4500 ft above sea level. See Table 8 for nominal burner
orifice size. High-altitude rating includes a 10 percent
derate as required by Canadian standards.

TABLE 6—MODEL 480BAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT RATE

(Tabulated Data Based on Altitude Up to 2000 Ft and 22,000 Btuh Per Burner)

GAS

HEAT

VALUE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.56

0.58

0.60

0.62

0.64

0.66

0.68

0.70

0.72

Orf

No.

Mnfld

Press.

Orf

No.

Mnfld

Press.

Orf

No.

Mnfld

Press.

Orf

No.

Mnfld

Press.

Orf

No.

Mnfld

Press.

Orf

No.

Mnfld

Press.

Orf

No.

Mnfld

Press.

Orf

No.

Mnfld

Press.

Orf

No.

Mnfld

Press.

860

41
42

3.2
3.6

41
42

3.3
3.7

41
42
40

3.4
3.8
3.2

41
40

3.5
3.3

41
39
40

3.7
3.2
3.4

41
39
40

3.8
3.3
3.5

39
40

3.4
3.6

38
39
40

3.2
3.5
3.7

38
39
40

3.3
3.6
3.8

875

42


3.4


41
42

3.2
3.6

41
42

3.3
3.7

41
42
40

3.4
3.8
3.2

41
40

3.5
3.3

41
39
40

3.6
3.2
3.4

41
39
40

3.8
3.3
3.5

39
40

3.3
3.6

38
39
40

3.2
3.4
3.7

890

42


3.3


42


3.4


41
42

3.2
3.6

41
42

3.3
3.7

41
42

3.4
3.8

41
40

3.5
3.2

41
40

3.6
3.3

41
39
40

3.7
3.2
3.4

41
39
40

3.8
3.3
3.5

905

42


3.2


42


3.3


42


3.4


41
42

3.2
3.6

41
42

3.3
3.7

41
42

3.4
3.8

41
40

3.5
3.2

41
40

3.6
3.3

41
39
40

3.7
3.2
3.4

920

43

3.8

42

3.2

42

3.3

42

3.4

41
42

3.2
3.5

41
42

3.3
3.7

41
42

3.4
3.8

41
40

3.5
3.2

41
40

3.6
3.3

935

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

41
42

3.2
3.5

41
42

3.3
3.7

41
42

3.4
3.8

41
40

3.5
3.2

950

43

3.6

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

41
42

3.2
3.5

41
42

3.3
3.6

41
42

3.4
3.7

965

43

3.4

43

3.6

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

41
42

3.2
3.5

41
42

3.3
3.6

980

44
43

3.8
3.3

42

3.5

43

3.6

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

41
42

3.2
3.5

995

44
43

3.7
3.2

44
43

3.8
3.4

43

3.5

43

3.6

43

3.7

43

3.8

42

3.2

42

3.3

42

3.4

1010

44

3.6

44
43

3.7
3.3

44
43

3.8
3.4

43

3.5

43

3.6

43

3.7

43

3.8

42

3.2

42

3.3

1025

44

3.5

44
43

3.6
3.2

44
43

3.7
3.3

43

3.4

43

3.5

43

3.6

43

3.7

43

3.8

43

3.2

1040

44

3.4

44

3.5

44
43

3.6
3.2

44
43

3.7
3.3

43

3.4

43

3.5

43

3.6

43

3.7

43

3.8

1055

44

3.3

44

3.4

44

3.5

44
43

3.6
3.2

44
43

3.8
3.3

43

3.4

43

3.5

43

3.6

43

3.7

1070

44

3.2

44

3.3

44

3.4

44

3.5

44
43

3.7
3.2

44
43

3.8
3.3

43

3.4

43

3.5

43

3.6

1085

45

3.8

44

3.2

44

3.3

44

3.4

44

3.6

44
43

3.7
2.3

44
43

3.8
3.3

43

3.4

43

3.5

1100

45

3.7

45

3.8
3.4

44

3.2

44

3.4

44

3.5

44

3.6

44
43

3.7
3.2

44
43

3.8
3.3

43

3.4

—12—

Summary of Contents for 480BAV Upflow

Page 1: ...the National Standard of Canada CAN CGA B149 1 and 2 M95 Natural Gas and Propane Installation Codes NSC NGPIC Wear safety glasses and work gloves Have fire extin guisher available during start up and...

Page 2: ...E VENT CONN SHIP WT LB 024045 14 3 16 12 9 16 12 11 16 4 122 036045 14 3 16 12 9 16 12 11 16 4 124 024065 14 3 16 12 9 16 12 11 16 4 132 036065 14 3 16 12 9 16 12 11 16 4 134 042091 17 1 2 15 7 8 16 4...

Page 3: ...tion details refer to the applicable instruction literature NOTE Remove all shipping brackets and materials before operating the furnace I LOCATION A General CAUTION Do not install furnace in a corros...

Page 4: ...s and screens must be considered If the free area of a louver or grille design is unknown it may be assumed that wood louvers have a 20 percent free area and metal louvers or grilles have a 60 percent...

Page 5: ...casing side and into the filler strip to secure it in place Filter should rest on the top of the filler strip when installed WARNING Never operate unit without a filter or with filter access door rem...

Page 6: ...Apply joint compound pipe dope sparingly and only to the male threads of each joint The compound must be resistant to the action of propane gas An accessible manual shutoff valve MUST be installed up...

Page 7: ...ode indicator light will flash rapidly and the furnace will not operate B 24 v Wiring Make field 24 v connections at the 24 v terminal strip See Fig 9 Connect terminal Y as shown in Fig 8 for proper c...

Page 8: ...HACR TYPE CKT BKR AMPS Maximum Minimum 024045 115 60 1 127 104 6 0 14 47 15 036045 115 60 1 127 104 8 3 14 34 15 024065 115 60 1 127 104 5 9 14 47 15 036065 115 60 1 127 104 8 7 14 32 15 042091 115 6...

Page 9: ...energizing the gas valve stopping gas flow to the burners The blower motor and EAC remain energized for 135 sec h Post purge The inducer motor remains energized 5 sec after the burners are extinguish...

Page 10: ...OMPONENT TEST TWIN TERMINAL TRAN TRANSFORMER 115VAC 24VAC JUNCTION UNMARKED TERMINAL PCB TERMINAL FACTORY WIRING 115VAC FACTORY WIRING 24VAC FIELD WIRING 115VAC FIELD WIRING 24VAC CONDUCTOR ON PCB FIE...

Page 11: ...llows a Momentarily jumper TEST and Com terminals until LED goes off b LED will display previous fault 4 times c Inducer motor operates for 10 sec then stops d Hot surface ignitor is energized for 15...

Page 12: ...0 62 0 64 0 66 0 68 0 70 0 72 Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press Orf No Mnfld Press...

Page 13: ...E CU FT HR SECONDS FOR 1 REVOLUTION SIZE OF TEST DIAL SECONDS FOR 1 REVOLUTION SIZE OF TEST DIAL 1 cu ft 2 cu ft 5 cu ft 1 cu ft 2 cu ft 5 cu ft 10 11 12 13 14 360 327 300 277 257 720 655 600 555 514...

Page 14: ...erature c After normal start up allow furnace to operate for 2 minutes then block flue outlet 100 percent Furnace should cycle off within 2 minutes d Remove blockage and reconnect vent pipe to furnace...

Page 15: ...oduct theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products...

Page 16: ...1996 BDP Co P O Box 70 Indianapolis IN 46206 Printed in U S A 16 480b454 Catalog No PA 3348 009...

Reviews: