background image

AN1173-AE

Net2

2

90°

Lockset

Door Frame

It is recommended that the PaxLock Pro is installed with a new lockcase to ensure the smooth operation 
of the PaxLock Pro. 
If an existing lock set is being used it must meet the following specifications:

 

• 

DIN 18251-1 certified for European locksets

 

• 

Backset of ≥55mm 

 

• 

Centres measurement of ≥70mm if using key override for European style locksets

 

• 

Centres measurement of ≥105mm if using key override for Scandinavian style locksets

 

• 

Turning angle of ≤45° 

The lockset must be both horizontally and vertically aligned to the door as shown in figure 2. 

It is best practice to ensure there is a gap of ≤3mm from the door edge to the frame. This is to ensure that 
if an anti-cord plunger is present on the lock case, it can function correctly. 

The door keep should also be ≤15mm to avoid clashing with the PaxLock Pro when the door is closed. 

Figure 2

Summary of Contents for PaxLock Pro

Page 1: ...nt to check that the door frame and any relevant door furniture are in good working order This is important to ensure both the longevity and smooth operation of the PaxLock Pro once installed The PaxLock Pro has been designed to work with locksets that are either European DIN 18251 1 or Scandinavian profile as shown in Figure 1 The through door holes must be 8mm diameter and the central follower m...

Page 2: ...using key override for European style locksets Centres measurement of 105mm if using key override for Scandinavian style locksets Turning angle of 45 The lockset must be both horizontally and vertically aligned to the door as shown in figure 2 It is best practice to ensure there is a gap of 3mm from the door edge to the frame This is to ensure that if an anti cord plunger is present on the lock ca...

Page 3: ...AN1173 AE Net2 3 Floor The distance between the bottom of the door and the floor must be sufficient to allow the door to freely open and close without rubbing on the floor Figure 3 ...

Page 4: ... the following must be checked If using in online mode the bridge may have to be positioned well within the 15m of range as a metal door will reduce the range of the bridge To ensure reliable operation standalone mode may be more appropriate The anti rotation tee nut should be replaced with an equivalent M4 self tapping pan head screw suitable for installation into metal not supplied Door Closer I...

Page 5: ...suitable for the PaxLock Pro you will need to ensure you have the right information to order the correct products There are 4 sales codes to choose from depending on whether you want an internal or external PaxLock Pro in either black or white Ordering the right kit When choosing the external version it is important to note that only the external side of the lockset is IP rated meaning the PaxLock...

Page 6: ...depending on the door width there are marks on the split spindle to aid in cutting it down Note When cutting down the split spindle we recommend a hack saw with 24 TPI teeth per inch It is important to note that when installing the Union HD72 lock case the screws on the follower must always be located on the inside of door as this denotes the direction of escape If they need to be moved over to th...

Page 7: ... sized for the PaxLock Pro To ensure the PaxLock Pro is perpendicular to the door edge it is important to mark and drill the anti rotation screw in the correct location as indicated below When passing the PaxLock Pro through the door to fit it the unit must sit completely flush against the face of the door If this is not the case the holes in the door may need adjusting ...

Page 8: ... following 1 Does the latch fully retract when depressing the handle 2 Does the door open smoothly without rubbing on the frame latch or floor 3 When letting go of the handle does the latch fully return to its natural position 4 Is it smooth and easy to open the door 5 When closing the door does the latch sit within the keep 6 When the door is closed does the deadbolt if present project smoothly i...

Page 9: ...he door is closed Failure to do this compromises the security of the door Check the distance from edge of door to frame is no more than 3mm Failure to do this can in some cases can cause lock case issues or compromise the security of the door To help improve the quality of the installation and the longevity of the product several common issues and potential solutions are listed below Troubleshooti...

Page 10: ...is closed The keep and strike plate may need to be moved if seals have been fitted without routing The door or frame may need shaving down to ensure smooth operation Door Furniture The through door cables have sheered when fitting the chassis There is free play in the handles The PaxLock Pro is not responding when I present a token This may be because the door is too narrow for the bolts that have...