18
User and installation instructions
EN – Installer information
New Installations
New installations require holes using a Ø110 mm
hole saw (Figure D).
5 mm
Ø 110 mm
D.
E.
F.
R75
45°
45°
45°
45°
G.
Pax wall pipes and external louvres are available as
accessories (Figure E). The fan’s wall seal has a short
spigot which fits inside the Ø100 mm pipe. Make
sure when mounting to adapt the length of the wall
pipe so it does not push back the wall seal so the
fan impeller cannot rotate. Always customise a wall
pipe, existing or new, so it ends about 5 mm inside
the wall surface where Levante is to be installed. The
wall frame with its seal is prepared with 5 cable entry
points (Figure F)
H.
I.
for concealed electrical connection or surface-
mounted cable using the dimension shown in
Figure G.
Make sure that the seal is properly installed on the
wall frame; place it in the appropriate place and
centre it in the wall pipe. The wall frame can be level-
led horizontally by placing a spirit level on its support
points (Figures H and I).
Use ageing-resistant sealant
to seal around cables that are
laid through the wall seal.