6 Assembly and installation [specialist]
12
99640141x-mub-en - V02
2017/07
WARNING
Risk to life and limb due to electric shock!
Prior to commencing electrical work on the controller, pull the mains plug!
Only after completing all installation work, plug the mains plug of the
controller into a socket. An unintentional start of the motors is thus
avoided.
NOTICE
Damage to property!
The location of installation must be dry, load-carrying, frost-proof and protected against
ultraviolet radiation in order to prevent material damage of the installation.
1.
Determine the mounting location of the
domestic hot water module near the buffer
tank. The pipes in the heating circuit must
not exceed a length of 4 m (for DN 20).
2.
Copy the measures for the mounting holes
to the wall. You can find a corresponding
drilling template (see on the right) on the
paper board under the domestic hot water
module.
3.
Drill the holes and insert adequate wall
plugs into the holes.
4.
Turn the screws into the wall plugs in such
a way that about 40 mm of each screw still
stick out.
5.
Remove the insulating front shell.
6.
Hang the domestic hot water module onto
the screws. Tighten the screws, so that the
sides of the insulation are flush to the wall.