3 Mounting and installation [specialist]]
2020/10
997655810x-mub-en – V08
9
1.
Remove the station from the packaging.
2.
Take off the insulating front shells.
3.
Screw the connecting piece [6] onto the
return connections of the 2-line station and
the 1-line station (see figure).
4.
Copy the mounting holes next to the
thermometers of the solar station to the
mounting surface.
5.
Drill the holes and mount the solar station
to the wall with appropriate wall plugs and
screws.
6.
Connect the solar station to the installation
by using the pipes
①
return to the collector field
⑨
return from storage tank 2
③
return from storage tank 1
④
flow towards storage tank 1 and 2
⑤
flow from the collector field
All thread connections have ¾" internal threads.