![PAW DN 20 Installation And Commissioning Instructions Download Page 8](http://html.mh-extra.com/html/paw/dn-20/dn-20_installation-and-commissioning-instructions_764049008.webp)
3 Mounting and installation [specialist]]
8
997655810x-mub-en – V08
2020/10
3
Mounting and installation [specialist]]
ATTENTION
Material damage due to high temperatures!
Since the solar fluid near the collector can be very hot, the group of fittings
must be installed at a sufficient distance from the collector field. It may be necessary to install
an intermediate tank in order to protect the expansion tank.
Not included in the scope of delivery!
Accessories: compression fitting
1.
Push the union nut ② and the cutting ring ③
onto the copper pipe ①. The pipe must
protrude at least 3 mm from the cutting ring
in order to ensure the force transmission
and the sealing.
2.
Insert the support sleeve
④ into the copper
pipe.
3.
Insert the copper pipe with the plugged-on
individual parts (②, ③ and ④) as far as
possible into the body of the compression
fitting ⑤.
4.
First, screw the union nut ② manually.
5.
Tighten the union nut ② by rotating one full
turn. Secure the body of the compression
fitting ⑤ against distort in order to avoid
damaging the sealing ring.