INSTALLATION
GENERAL INFORMATION
The DAT 200 consists of a motherboard, to which are added the options available, accommo-
dated in a plastic enclosure for DIN rail 35mm.
The DAT 200 should not be immersed in water, subjected to jets of water and cleaned
or washed with solvents.
Do not expose to heat or direct sunlight.
OVERALL DIMENSIONS
ELECTRICAL INSTALLATION
DAT 200 is equipped with removable screw, pitch 5.08 mm.
The load cell cable must be shielded and channeled away from power cables to pre-
vent electromagnetic interferences.
INSTRUMENT POWER SUPPLY
The instrument is powered through the terminals 23 and 24. The
power supply cable must be channeled separately from other cables.
The internal circuit is galvanically isolated from the supply voltage.
Power supply voltage: 24 Vdc± 10%, max. 2W
Summary of Contents for DAT 200