CRISTAL FM 1/2 OVENS Translated manual N°AF220045170-17
26802 Portes Les Valence – France
26
RECOMMENDATIONS for ELCO or CUENOD BURNERS
Pipe dimensions
SINGLE-PIPE SYSTEM PRESSURE SIDE
SINGLE-PIPE SYSTEM SUCTION SIDE
GPH
NOZZLE
0.5
0.6
0.8
1
1.5
2
D(mm)
H(m)
4
4
4
4
4
6
4
6
0
90
75
56
45
30
150
22
113
0.5
100
83
63
50
33
150
25
126
1
110
92
69
55
37
150
27
139
2
131 109
82
65
44
150
33
166
3
152 126
95
76
50
150
38
192
4
172 144 108
86
57
150
43
218
GPH
NOZZLE
0.5
0.6
0.8
1
1.5
2
D(mm)
H(m)
4
4
4
4
4
6
4
6
0
90
75
56
45
30
150
22
113
0.5
76
66
50
40
26
134
20
100
1
69
57
43
34
23
116
17
87
2
48
40
30
24
16
80
12
61
3
28
23
17
14
9
47
7
35
4
7
6
4
0
0
12
0
9
TWIN-PIPE SYSTEM PRESSURE SIDE
TWIN-PIPE SYSTEM SUCTION SIDE
HEIGHT
PIPE OUTER DIAMETER d (mm)
m
4
6
8
10
0
2
15
50
124
0.5
2
16
56
138
1
2
18
61
150
2
3
22
73
150
3
4
26
85
150
4
4
30
97
150
HEIGHT
PIPE OUTER DIAMETER d (mm)
m
4
6
8
12
0
15
50
124
150
0.5
13
44
109
150
1
11
38
95
150
2
7
26
66
138
3
3
14
37
79
4
0
0
8
19
* Single-pipe system suction side
We thoroughly recommend the use of a prefilter linked to the pump by twin pipes - this allows for manual or
automatic draining of the installation.
Open the drain cock during burner inhibition and only close when oil flows through the drain cock. The volume of
residual air in the pump will be eliminated through the nozzle.
The pump is not amenable to conversion from a twin pipe to a single pipe configuration.
Maximum lengths (intersection of a line and a column) are indicated in metres and have been calculated with four
elbows, 1 stop valve and 1 check valve. In the event of additional limitation, this length should be reduced by
equivalent values as regards head loss.
Examples:
Twin pipe system suction side:
- Suction height: 1 metre
- Length of pipes between the burner and the tank bottom: 25 metres
Pipes with an internal diameter of 8 mm (6 mm is too small as max. length = 10 metres) should be used.
Single pipe system pressure side:
- Nozzle used: 2 gph
- Distance between tank bottom and burner: 0.5 metre
- Pipe length: 70 metres
Pipes with an internal diameter of 6 mm (4 mm is too small as max. length = 24 metres) should be used.