RECOMMENDED MAINTENANCE
CONTINUED
Mantles. Use Paulin mantles which are designed for use with propane and butane gas only. Never use broken
mantles. Inspect for carbon deposits each time gaslight is used. Clean or replace defective mantles immediately.
Use proper ceramic burner nose and mantle combination. (Example: “Tie-On” type burner nose, #L12-11A, with
tie-on mantles, #L13-6. Or “Pre-formed” type burner nose, #L12-2A, with pre-formed mantles, #L13-2.) Also see
“Mantle Installation and Lighting Instructions.”
Burner Nose Screen. Screen must be in threaded end of burner nose. Gaslight will not function properly if screen is
missing.
Seal. Seal is placed on threaded end of burner nose. Seal and burner nose should be screwed securely into bunsen.
The seal must be replaced anytime the burner nose is removed after the lamp has been used.
Bunsen. Flow of combustion air and ventilation air must not be obstructed. To ensure proper air flow and gas mixture,
the inside of the bunsen must be clean and free of any material that may potentially accumulate, such as spider webs,
insects, etc. Make a periodic visual check of the Bunsen. The Bunsen can be cleaned by drawing a clean, dry cloth
through it. It can also be cleaned by blowing it out with compressed air. Never attach a mantle directly to the Bunsen.
BUNSEN CLEANING INSTRUCTIONS
1. Remove burner nose.
2. Pull a clean, dry cloth
through Bunsen to clean
out foreign material.
3. Replace seal.
Reassemble burner
nose and tighten securely.
Note: Always replace seal if
lamp has been previously lit.
or L13-8 Quick-Clip