7
Liability
The CLIMOS was developed and manufactured for use in so-called comfort ventilation systems. Any other use is
considered as “improper use” and can result in damages to the CLIMOS or in personal injuries, for which the
manufacturer cannot be made liable. The manufacturer is not liable for any damage, which is due to the following
causes:
•
Non-observance of the notes on safety, operation and maintenance, stated in this manual
•
The installation was not performed according to the regulations
•
Mounting of the spare parts, which were not delivered and prescribed by the manufacturer
•
The defects occur due to incorrect connection, improper use or soiling of the system
•
Normal
wear
2
Hints for the operator and the qualified personnel
Product
description
The CLIMOS is a ventilation device with heat recovery for healthy, balanced and energy-saving comfort ventilation. A
comfort ventilation system consists in exhausting stale, odorous air for example from the kitchen, the bathroom,
W.C.s and in introducing an equal quantity of fresh air into living rooms, bedrooms and children’s rooms.
For heat recovery, the CLIMOS is equipped with a membrane moisture heat exchanger (enthalpy exchanger) which,
due to its physical properties, is not only able to transfer heat, but also moisture. The use of moisture sensors for limit
monitoring in rooms with high humidity rise is recommended. The casing is made of powder-coated sheet metal with
anthracite colouring. The internal lining made of high-quality polypropylene provides the necessary heat insulation
and device noise protection.
The CLIMOS is equipped with an integrated defroster heater. The design of layout air connection is available in the
construction types A or B. Amongst others, the type plate informs about the construction types.
The CLIMOS includes two maintenance-free 230 Vac radial fans with the integrated power supply unit and electronic
commutation. The volume flow constant fans keep the air quantity at a constant speed for each selected fan rotary
speed. The air quantity is also not affected by soiled filters.
By default, a filter in class ISO Coarse
≥
70 % (M5) is used in the unit for the outdoor air and the extract air. As an
option, filters in class ISO ePM1
≥
60 % (F7) can be used for the outdoor air.
They consist of a synthetic woven filter medium with a frame made of polypropylene.