The thermostat switches on and off one or more loads (e.g. heated drinking bowls) up to a total load of 16A  
(2.5 A with motor load).
This is important for the operation of heating drinking systems, so that the heating is switched on immediately in the 
case of frost. Otherwise the heating is switched off when the set temperature values are reached. The thermostat is  
resistant against ammoniacal steam, such as stable air. The set value (scale value) is adjusted at the rotary switch. 

The sensor must be able to notice all temperature influences. It should be placed with plenty of air circulation, not in 
"dead" corners or in the vicinity of cooling or heating areas or windows. Direct sunlight should be avoided. The  
temperature sensor and the unit should be cleaned regularly.

After removing the rotary switch and the upper cover, fix the unit to the wall. It‘s only usable for connecting to  
permanently installed lines.

Errors in the connection can damage the unit! No liability is accepted for damage caused by incorrect 

connection and/or improper handling!  

 

Before working on the unit, make sure all cables are voltage free! The connection must only be made by authorised 
expert personnel! Connect the unit as shown on the enclosed simplified diagram. The VDE 0100, especially parts 705 
and EN 60730 (part 1), have to be considered. If the unit does not work, first check the connection and the power 
supply.

Application, function, operation

Positioning, maintenance

Mounting

Dimensions

1.

2.

3.

4.

Protection class IP 54
Wall mounting
Individual limitation of

the control range

Summary of Contents for 381510

Page 1: ...tallation Instructions Montagehandleiding Instrucciones de montaje DEUTSCH F r den Aufbau wird zus tzlich ben tigt Aufbau mit einer Person in ca 1 h Anschlusskabel 230 V 3 x 1 5 mm NYM je nach Leitung...

Page 2: ...genauigkeit 1 5 bei 50 C 6 bei 0 C Geh use Ma e ca 80 x 150 x 70 mm b x h x t Schutzklasse Schutzart IP 54 Max zul Schaltstrom Kl 1 2 ffnungskontakt 16 2 5 A 230 V AC z B Heizkabel Transformator Umsch...

Page 3: ...n Der Temperaturf hler und das Geh use sollten regelm ig von Schmutz befreit werden Nach Abnahme des Einstellknopfes und des Geh useoberteils wird das Ger t an der Wand befestigt Der Thermostat ist nu...

Page 4: ...taje PATURA KG Germany Tel 00 49 93 72 94 74 0 www patura com Mainblick 1 63925 Laudenbach Fax 00 49 93 72 94 74 29 info patura com 220725 ZANL 381510 A3 Thermostat Verteilerdose Transformator Heizkab...

Page 5: ...0 Thermostat pour protection antigel Frostschutz Thermostat Frost Protection Thermostat Tegen vorst beschermende thermostaat Termostato de protecci n antihielo C ble de raccordement 230 V 3 x 1 5 mm N...

Page 6: ...iante max admissible 30 80 C Diff rentiel de commutation 1 5 2 C Tol rance 1 5 50 C 6 0 C Bo tier dimensions env 80 x 150 x 70 mm l x h x t Classe et indice de protection IP 54 Courant d enclenchement...

Page 7: ...soleil Le capteur de temp rature et le bo tier doivent tre r guli rement nettoy s Apr s avoir retir le bouton de r glage et la partie sup rieure du bo tier l appareil est fix au mur Il est uniquement...

Page 8: ...Germany Tel 00 49 93 72 94 74 0 www patura com Mainblick 1 63925 Laudenbach Fax 00 49 93 72 94 74 29 info patura com 5 Raccordement 6 ZANL 381510 A3 Sch ma de raccordement Thermostat Bo tier de raccor...

Page 9: ...screw 4 0 x 40 mm Nylon Dowel 6 mm Slotted Screwdriver Cordless Screwdriver and BIT Set for wood thread screws Side Cutter Cable Stripper ENGLISH Mounting with one person in approx 1 h Additionally r...

Page 10: ...curacy 1 5 at 50 C 6 at 0 C Housing dimensions ca 80 x 150 x 70 mm w x h x d Protection class IP 54 Max perm switching current Kl 1 2 open contact 16 2 5 A 230 V AC e g heating cable transformers Swit...

Page 11: ...unlight should be avoided The temperature sensor and the unit should be cleaned regularly After removing the rotary switch and the upper cover fix the unit to the wall It s only usable for connecting...

Page 12: ...ontaje PATURA KG Germany Tel 00 49 93 72 94 74 0 www patura com Mainblick 1 63925 Laudenbach Fax 00 49 93 72 94 74 29 info patura com Thermostat Junction box Transformer Heating cable 6 12mm 11 13mm J...

Page 13: ...4 0 x 40 mm Plug 6 mm Gegroefde schroevendraaier Accu schroevendraaier en passende BIT inlage voor houtdraadschroef Zijsnijder Kabelstripper NEDERLAND Montage met een persoon in ca 1 h Voor de montage...

Page 14: ...omgevingstemperatuur 30 80 C Schakeldifferentieel 1 5 2 C Schakelnauwkeurigheid 1 5 bij 50 C 6 bij 0 C Behuizing Maten ca 80 x 150 x 70 mm b x h x t Beschermingsklasse beschermingstype IP 54 Max toel...

Page 15: ...eden De temperatuursensor en de behuizing moeten regelmatig van vuil worden ontdaan Nadat de afstelknop en het bovenste deel van de behuizing zijn verwijderd wordt het toestel aan de muur bevestigd He...

Page 16: ...e PATURA KG Germany Tel 00 49 93 72 94 74 0 www patura com Mainblick 1 63925 Laudenbach Fax 00 49 93 72 94 74 29 info patura com Thermostaat Ansluitdoos Transformator Verwarmingskabel 6 12mm 11 13mm T...

Page 17: ...ado para madera 4 0 x 40 mm Taco 6 mm Destornillador ranurado Destornillador inal mbrico e inserto BIT para tornillo de rosca de madera Cortador lateral Pelacables ESPA OL 0049 9372 9474 243 Montaje p...

Page 18: ...Carcasa Dimensiones aprox 80 x 150 x 70 mm l x a x a Clase y grado de protecci n IP 54 Corriente de conmutaci n m x permitida Cl 1 2 contacto de apertura 16 2 5 A 230 V AC por ejemplo cable calefacto...

Page 19: ...star expuesto a la circulaci n del aire y no debe montarse en esquinas muertas o en la proximidad inmediata de superficies de calefacci n y refrigeraci n o ventanas Debe evitarse la luz solar directa...

Page 20: ...RA KG Germany Tel 00 49 93 72 94 74 0 www patura com Mainblick 1 63925 Laudenbach Fax 00 49 93 72 94 74 29 info patura com Termostato Caja de empalme Transformador Cable calefactor 6 12mm 11 13mm Caja...

Reviews: