Introduction
24
Model 3088A Series User Manual
2 • Configuration
S4-2 through S4-8: Data Rate
Switches S4-2 through S4-8 define both the DSL line rate and the serial data rate.
Note
For
3088A/K models
, only columns
S4-4
through
S4-8
apply in this table.
Also, use
S4-1
to configure the
Line Build Out
:
OFF
= 75 ohms,
ON
= 120 ohms.
Table 5. S4-2 through S4-8 Data Rate DIP switch settings
S4-2
S4-3
S4-4
S4-5
S4-6
S4-7
S4-8 Data Rate (kbps)
OFF
OFF
OFF
OFF
OFF
OFF
ON
192
OFF
OFF
OFF
OFF
OFF
ON
OFF
256
OFF
OFF
OFF
OFF
OFF
ON
ON
320
OFF
OFF
OFF
OFF
ON
OFF
OFF
384
OFF
OFF
OFF
OFF
ON
OFF
ON
448
OFF
OFF
OFF
OFF
ON
ON
OFF
512
OFF
OFF
OFF
OFF
ON
ON
ON
576
OFF
OFF
OFF
ON
OFF
OFF
OFF
640
OFF
OFF
OFF
ON
OFF
OFF
ON
704
OFF
OFF
OFF
ON
OFF
ON
OFF
768
OFF
OFF
OFF
ON
OFF
ON
ON
832
OFF
OFF
OFF
ON
ON
OFF
OFF
896
OFF
OFF
OFF
ON
ON
OFF
ON
960
OFF
OFF
OFF
ON
ON
ON
OFF
1024
OFF
OFF
OFF
ON
ON
ON
ON
1088
OFF
OFF
ON
OFF
OFF
OFF
OFF
1152
OFF
OFF
ON
OFF
OFF
OFF
ON
1216
OFF
OFF
ON
OFF
OFF
ON
OFF
1280
OFF
OFF
ON
OFF
OFF
ON
ON
1344
OFF
OFF
ON
OFF
ON
OFF
OFF
1408
OFF
OFF
ON
OFF
ON
OFF
ON
1472
OFF
OFF
ON
OFF
ON
ON
OFF
1536
OFF
OFF
ON
OFF
ON
ON
ON
1600
OFF
OFF
ON
ON
OFF
OFF
OFF
1664
OFF
OFF
ON
ON
OFF
OFF
ON
1728
OFF
OFF
ON
ON
OFF
ON
OFF
1792
OFF
OFF
ON
ON
OFF
ON
ON
1856
OFF
OFF
ON
ON
ON
OFF
OFF
1920
OFF
OFF
ON
ON
ON
OFF
ON
1984
OFF
OFF
ON
ON
ON
ON
OFF
2048
OFF
OFF
ON
ON
ON
ON
ON
2112
OFF
ON
OFF
OFF
OFF
OFF
OFF
2176