Configure the IP address
18
3088/I Getting Started Guide
2 • Initial configuration
Figure 3. DC Power Supply
Power-up indication
The
Power
and
100M Ethernet
LEDs are lit while the RocketLink-G is powering up.
Configure the IP address
The RocketLink-G NTU is shipped with a factory-configured IP address assigned to the
Ethernet
LAN port
(green outline). The address is
192.168.200.10/24
. In most cases, you must change the address to be on the
same subnet as your PC, as described in the procedures below. If you are not sure which IP address to use for
your installation, contact your network administrator.
Connect a PC and log in
Using the included combination RS-232/Ethernet cable and DB9-RJ45 adapter, connect a PC’s serial port to
the RocketLink-G’s
Console
port (red outline) (see
Figure 4. Connecting RocketLink-G NTU to the PC’s serial port
There are no user-servicable parts in the power supply section of
the Model 3088/I. Fuse replacement should only be performed
by qualified service personnel. See Chapter 8,
The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.
To Power
Supply Jack
To -48VDC
Source
-Vin
+Vin
SWITCHING POWER SUPPL
Y
MODEL
: SYD1
106-0505
INPUT
: 36-60V 0.2A
MAX
OUTPUT
: +5V 1.0A
OUTPUT
POWER : 5W MAX
S/N
: G01234567890
MADE IN CHINA
BY
SUNNY
Black lead (-V)
Red lead (+V)
Barrel power connector
WARNING
CAUTION
MDI-X
Line
Ethernet
Power
Console
Connect to Console port
Serial port
PC with
terminal emulator