background image

 

 

 

 

 

 

 

 

 

 
 
 
 
 

Patton Electronics Company, Inc. 

7622 Rickenbacker Drive 

Gaithersburg, MD 20879 USA 

Tel: +1 (301) 975-1000 

Fax: +1 (301) 869-9293 

Support: +1 (301) 975-1007 

Web: 

www.patton.com 

E-mail: 

[email protected] 

 

Trademark Statement 

The terms 

SmartNode, SmartWare and SmartView 

are trademarks of Patton 

Electronics Company. All other trademarks presented in this document are the 

property of their respective owners. 

 
 

Copyright © 2004–2005, Patton Electronics Company. All rights 

reserved. 

The information in this document is subject to change without notice. Patton 

Electronics assumes no liability for errors that may appear in this document. 

 

Important Information 

To use virtual private network (VPN) and/or AES/DES/3DES encryption 

capabilities with the SmartNode 4552, you may need to purchase additional 

licenses, hardware, software, network connection, and/or service. Contact 

[email protected] or +1 (301) 975-1000 for assistance. 

 

ii 

Summary of Contents for SMARTNODE 4552

Page 1: ...nterfaces BRI So Zulassung Zugelassen fur die Anshaltung an da offentliche ISDN Telekommunikatinosnetz an BRI So ISDN Schnittstellen Approval This device is approved for connection to the public ISDN...

Page 2: ...re the property of their respective owners Copyright 2004 2005 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Electronics as...

Page 3: ...patton com voip Your SmartNodes can be used for a wide variety of IP and voice over IP applications To support and ease the configuration of the SmartNodes configuration templates for the most import...

Page 4: ...they must be changed Contact your network administrator if you are not sure what IP address to use in your installation PC connection and Login To access the SmartNode configuration connect a PC with...

Page 5: ...te network 172 16 1 0 is assumed The IP address is set to 172 16 1 100 172 16 40 1 ctx ip router interface eth0 172 16 40 1 if ip eth0 ipaddress 172 16 1 100 255 255 255 0 2002 10 29T00 09 40 LOGINFO...

Page 6: ...nfiguration to a TFTP server The SmartNode can now load its configuration from this server In this example we assume the TFTP server is running on the PC with the IP address 172 16 1 10 and the config...

Page 7: ...resp SN1400 0001 0001 must use at least the following Builds of SmartWare Build 21211 for Release 2 01 Build 21209 for Release 2 02 Build 21182 for Release or any Build for all subsequent Releases The...

Page 8: ...ed No part of this publication may be reproduced without prior written permission from Inalp Networks AG dba Patton Inalp AG Patton Inalp AG reserves the right to make changes in specifications and ot...

Reviews: