Power Connection and Default IP Configuration 

First the SmartNode must be connected to the mains power supply using the included power supply. Wait 
until the ‘PWR' LED stops blinking and lights constantly. Now the SmartNode is ready. 
 
The factory default IP settings are as follows: 
LAN ports (green, ETH 0/1): 

IP Address:  192.168.1.1 Network 

Mask: 

255.255.255.0 

WAN port (red, ETH 0/0): 

IP Address:  172.16.40.1 Network 

Mask: 

255.255.0.0 

 
A DHCP Server with address space 192.168.1.10 – 192.168.1.19 is running on the LAN ports 
Both Ethernet ports are pre-configured and active. 
 
If these addresses conflict or do not match with your network they must be changed. Contact your network 
administrator if you are not sure what IP address to use in your installation. 
 

PC connection and Login 

To access the SmartNode configuration connect a PC with Ethernet port to one of the LAN ports (green) of the 
SN4552. Use the included black Ethernet cable for this purpose. Set your PCs TCP/IP configuration to DHCP 
to automatically receive an IP address from the SmartNode. 

 

Open a Telnet connection to the default LAN IP address of the SmartNode (192.168.1.1). Use the Terminal 
program included with most PC operating systems (e.g. Hyper Terminal on Windows). The CD-ROM also 
includes some recommended terminal programs. 
 
The factory default login is 
Login name: 

administrator 

Password: <empty> 
 
So use the name 

administrator 

after the login prompt and simply press the Enter key after the password 

prompt.  
 

login:

administrator

 

password: 

172.16.40.1> 

 

 

Summary of Contents for SMARTNODE 4552

Page 1: ...nterfaces BRI So Zulassung Zugelassen fur die Anshaltung an da offentliche ISDN Telekommunikatinosnetz an BRI So ISDN Schnittstellen Approval This device is approved for connection to the public ISDN...

Page 2: ...re the property of their respective owners Copyright 2004 2005 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Electronics as...

Page 3: ...patton com voip Your SmartNodes can be used for a wide variety of IP and voice over IP applications To support and ease the configuration of the SmartNodes configuration templates for the most import...

Page 4: ...they must be changed Contact your network administrator if you are not sure what IP address to use in your installation PC connection and Login To access the SmartNode configuration connect a PC with...

Page 5: ...te network 172 16 1 0 is assumed The IP address is set to 172 16 1 100 172 16 40 1 ctx ip router interface eth0 172 16 40 1 if ip eth0 ipaddress 172 16 1 100 255 255 255 0 2002 10 29T00 09 40 LOGINFO...

Page 6: ...nfiguration to a TFTP server The SmartNode can now load its configuration from this server In this example we assume the TFTP server is running on the PC with the IP address 172 16 1 10 and the config...

Page 7: ...resp SN1400 0001 0001 must use at least the following Builds of SmartWare Build 21211 for Release 2 01 Build 21209 for Release 2 02 Build 21182 for Release or any Build for all subsequent Releases The...

Page 8: ...ed No part of this publication may be reproduced without prior written permission from Inalp Networks AG dba Patton Inalp AG Patton Inalp AG reserves the right to make changes in specifications and ot...

Reviews: