4.2   CONNECTING THE SERIAL PORT 

The serial port interface on the Model 1095 uses interchangeable

QuikConnect™ Modules. Each QuikConnect™ Module has a 50-pin
card edge connector on one side and a serial port interface on the
other. Figure 4  below shows how a 

QuikConnect™ Module plugs into

the back of the Model 1095.

4.2.1   Changing 

QuikConnect™ Modules

When you purchase a particular version of the Model 1095, it

should be shipped to you with the appropriate 

QuikConnect™ Module

already installed. If you need to install a different 

QuikConnect™

Module, follow these steps:

Removing the Existing 

QuikConnect™ Module 

1)  Turn the power switch off. Leave the power cord plugged into a

grounded outlet to keep the unit grounded.

2)  Loosen the two thumbscrews on the module by turning them

counterclockwise.

3)  Grasp the two thumbscrews and gently pull the module from

the unit. Apply equal force to the thumbscrews to keep the
module straight during the removal process

Installing the New 

QuikConnect™ Module 

1)  Make sure the power switch is off. Leave the power cord

plugged into a grounded outlet to keep the unit grounded.

18

0 OFF

1 ON

Line

Interf

ace P

or

t

Figure 5. Installation of Model 1095 Plug-in Serial Interface Module

17

2)  Hold the module with the faceplate toward you and align the

module with the guide slots in the rear panel of the Model
1095.

3) While keeping the module’s faceplate parallel with the Model

1095 rear panel, slide the module straight in – so that the card
edge contacts line up with the socket inside the chassis.

4) With the card edge contacts aligned with the socket, firmly seat

the module by using your thumbs to apply pressure directly to
the right and left edges of the module faceplate. Applying mod-
erate and 

even pressure should be sufficient to seat the mod-

ule. You should hear it “click” into place.

5) To secure the module in place, push the thumbscrews into the

chassis and turn the screws clockwise to tighten.

4.2.2   Connecting to a “DTE” Device 

The serial port on most 

QuikConnect™ interface modules (all

except the X.21 module) is hard-wired as a DCE. Therefore these
modules “want” to plug into a DTE such as a terminal, PC or host.
When making the connection to your DTE device, use a straight
through 
cable of the shortest possible length—we recommend 6 feet
or less. When purchasing or constructing an interface cable, please
refer to the pin diagrams in Appendix C as a guide.

4.2.3   Connecting to a “DCE” Device

If the Model 1095’s QuikConnect™ interface module is hard-wired

as a DCE (all except the X.21 module), you must use a 

null modem

cable when connecting to a modem, multiplexer or other DCE device.
This cable should be of the shortest possible length—we recommend
6 feet or less. When purchasing or constructing a null modem inter-
face cable, use the pin diagrams in Appendix C as a guide.

NOTE:

The card edge connector should meet the socket when

it is almost all the way into the chassis. If you encounter a lot of
resistance, remove the module and repeat steps 2 & 3.

NOTE:

Pin-out requirements for null modem applications vary

widely between manufacturers. If you have any questions about
a specific application, contact Patton Electronics Technical
Support.

Summary of Contents for NetLink 1095

Page 1: ...1095 NetLink mDSL Multi Rate Symmetric DSL Modem Part 07M1095 F Doc 033051UF Revised 06 08 00 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com C E R T I F I E D An ISO 9001...

Page 2: ...above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings an...

Page 3: ...the ability to deliver the maximum bit rate that a twisted pair line can accommodate Supporting multiple line rates from 144kbps to 2 320Mbps the NetLink provides megabyte speeds to leased line LAN to...

Page 4: ...position See Figure 2 5 Figure 2 Close Up of Configuration Switches all sets are identical in appearance Figure 1 Underside of Model 1095 Showing Location of DIP Switches Front Back On S3 S2 S1 Off 3...

Page 5: ...ositions of DIP Switch S3 Detailed descriptions of each switch follow the table Switch S3 1 DTE Rate Use Switch S3 1 through S3 6 to set the DTE bit rate S3 1 S3 2 S3 3 S3 4 S3 5 S3 6 DTE Rate kbps Of...

Page 6: ...Model 1095 To construct an RS 232 to EIA 561 patch cable refer to the control port pinout dia gram in Appendix F Refer to Appendix B to order a pre made cable 2 Power up the terminal and set its RS 2...

Page 7: ...ing up your unit to ensure security for your network After entering the correct password the Model 1095 will display the Software Configuration Menu described below 3 3 2 Software Configuration Menu W...

Page 8: ...disable loop backs from the DTE interface The DTE Loopback Request menu is shown in the following diagram If the IM1 I Quick Connect Module is installed select 2 Disable Response to DTE Loopback Requ...

Page 9: ...ed system using the Model 1001MC and 1095RC cards installed in Patton s 2U rack system In this application the system administrator can configure the entire rack through the Network Management Station...

Page 10: ...p with the socket inside the chassis 4 With the card edge contacts aligned with the socket firmly seat the module by using your thumbs to apply pressure directly to the right and left edges of the mod...

Page 11: ...ranging from 100 to 253 VAC with no re configuration necessary see Appendix B for available domestic and international power cords DC Power Supply option Model 1095 DC operates in 48 VDC environments...

Page 12: ...l Port Local Normal Remote 511E Normal 511 Figure 6 Model 1095 Front Panel NetLinkTM mDSL Model 1095 High Speed Modem 21 22 ER blinks ON OFF after a 511 511E test has timed out See Section 5 3 3 Test...

Page 13: ...rds the local DTE In a Remote Loop the data is looped back to the line but it is also allowed to pass through to the framer and to the remote DTE 23 24 Restart Procedure The restart procedure is in pl...

Page 14: ...In the second path data presented at the far end DTE will be transmitted to the local DTE and then looped back within the local DTE Loop Control block with the Processor After the Local Loop is desel...

Page 15: ...Framer Line 27 28 Remote Digital The Remote Loop uses the EOC channel an Loop out of band signaling channel to establish the remote link Upon the RDL switch being thrown or DTE initiation a RDL_ON Req...

Page 16: ...Mode it is possible to 511 511E Pattern turn on the 511 511E pattern generators on Generators both ends of the link Once a 511 511E pattern is selected on one end of the link the pattern generator wil...

Page 17: ...ne to the other Model 1095 While one operator initiates test the other monitors for errors 31 32 APPENDIX A PATTON ELECTRONICS MODEL 1095 SPECIFICATIONS Transmission Format Synchronous Transmission Li...

Page 18: ...07M1090SVC 1090 Series Service Manual 12F 561 DB 25 to EIA 561 12M 561 DB 25 to EIA 561 33 34 APPENDIX C PATTON ELECTRONICS MODEL 1095 INTERFACE PIN ASSIGNMENT RS 232 RS 530 Interface Pin Description...

Page 19: ...4 42980 8 1 13 2 55260 10 4 17 0 64470 12 2 19 8 70610 13 4 21 7 90784 17 2 27 9 272 192 256 20300 3 8 6 2 30600 5 8 9 4 42840 8 1 13 2 55080 10 4 16 9 61200 11 6 18 8 70380 13 3 21 7 90488 17 1 27 8...

Page 20: ...DTE Connected With DTE Connected Mark O O G G G off off off O O G G G off off off Space G G G G G off off off G G G G G off off off Data GO GO G G G off off off GO GO G G G off off off Link Brk DSL L...

Reviews: