background image

 

USER 

 

MANUAL

 

MODEL 2172

 

CopperLINK™ High Speed 
Ethernet Extenders

 

SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007

 

Part# 07M2172-UM
Doc# 03333U2-001
Rev. B
Revised 12/4/08

 

An ISO-9001Certified

Company

 

This is a Class A device and is intended for use in a 
light industrial environment. It is not intended nor 
approved for use in an industrial or residential 
environment.

Summary of Contents for CopperLINK 2172

Page 1: ... 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M2172 UM Doc 03333U2 001 Rev B Revised 12 4 08 An ISO 9001Certified Company This is a Class A device and is intended for use in a light industrial environment It is not intended nor approved for use in an industrial or residential environment ...

Page 2: ...guration 12 4 1 Configuring the hardware DIP switches 12 4 2 Configuring DIP Switch S2 14 Switch S2 1 Symmetric Asymmetric Operation 14 Switches S2 2 and S2 3 Data Rate 14 5 0 Operation 16 5 1 Power Up 16 5 2 Front Panel LED Status Monitors 17 A Specifications 18 A 1 LAN Connection 18 A 2 Transmission Line 18 A 3 CopperLINK Line Rate and CopperLINK Distance 18 A 4 CopperLINK Surge Suppressor 18 A ...

Page 3: ...3 RJ 45 20 Terminal Block 20 D Distance Chart Based on 24 AWG 0 5 MM 21 ...

Page 4: ...ed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user Note Conformity documents of all Patton products can be viewed online at www patton com under the appropriate product page 1 1 COMPLIANCE EMC Compliance FCC Part 15 Class A EN55022 Class A EN55024 Safety Compliance IEC EN 60950 1 AS NZS 60950 1 1 2 RADIO AND TV INTERFERENCE FCC PART 1...

Page 5: ...approximation of the laws of the member states relating to electrical equipment designed for use within certain voltage limits The safety advice in the documentation accompanying this product shall be obeyed The conformity to the above directive is indicated by the CE sign on the device 1 4 AUTHORIZED EUROPEAN REPRESENTATIVE D R M Green European Compliance Services Limited Avalon House Marcham Roa...

Page 6: ...o a wall outlet which has earth ground Hazardous network voltages are present in WAN ports regardless of whether power to the unit is ON or OFF To avoid electric shock use caution when near WAN ports When detaching the cables detach the end away from the device first Do not work on the system or connect or disconnect cables during periods of lightning activity In accordance with the requirements of...

Page 7: ...D indicators for Power Link and Ethernet Link Activity Surge suppression up to 20 kA 8 20 μs Made in the USA 2 2 DESCRIPTION The Patton Electronics Model 2172 CopperLink modems provide high speed LAN connections between peered Ethernet LANs remote PC s or any other network enabled 10 100Base T device Operating in pairs one Model 2172 is configured as the L Local unit located at one end of the LAN e...

Page 8: ... 1 Connecting the Twisted Pair Line Interface on page 9 Note See Figure 2 for the standalone unit s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting the 10 100Base T Ethernet Interface on page 11 3 Connect the power plug refer to section 3 3 Connecting Power on page 12 The Interconnecting cables shall be acceptable for external use and shall be rated for the...

Page 9: ...ured as a R Remote unit It does not matter which end is the L and which is the R The link is always initiated by the R unit As long as the L unit is powered on the R unit can establish a link by being powered on or by having its power reset The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem ...

Page 10: ...bserve the sig nal pin relationships on the Model 2172 s CopperLINK interface jacks The RJ 45 connector on the Model 2172 s twisted pair interface is polar ity insensitive and is wired for a two wire interface The signal pin rela tionship is shown in Figure 3 Figure 3 Model 2172 RJ 45 twisted pair line interface The terminal block connector on the Model 2172 s twisted pair interface is polarity in...

Page 11: ...connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long Figure 5 Model 2172 10 100Base T RJ 45 Connector Pinout The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem perature flammability and mechanical serviceability Ethernet Power Made in the USA ...

Page 12: ...be regulated 5VDC 5 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions 4 0 CONFIGURATION The Model 2172 has eight DIP switches for configuring the unit for a wide variety of applications This section describes switch locations and explains the different configurations 4 1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat tip screwdriver remove...

Page 13: ... and Off positions Figure 7 DIP switch orientation P o w e r L in k E th e rn e t C o p p e r L I N K H i g h S p e e d E t h e r n e t E x t e n d e r 1 2 3 4 ON Push toggle up for ON position Switch toggle Push toggle down for OFF position 1 2 3 4 ON S2 S2 5 6 7 8 5 6 7 8 S2 1 2 3 4 ON 5 6 7 8 S2 Rear Front ...

Page 14: ...2 3 Data Rate Use switches S2 1 S2 2 and S2 3 to configure the CopperLINK line rates Note See Appendix D on page 21 for line rate distances Table 1 S2 Summary Position Description S2 1 Symmetric Asymmetric S2 2 Line Rate S2 3 Line Rate S2 4 Ethernet configuration S2 5 Ethernet configuration S2 6 Ethernet configuration S2 7 Ethernet Shutdown S2 8 Remote Configuration Table 2 Ethernet Auto Sense Selectio...

Page 15: ...ngs Table 4 Asymmetric CopperLINK Line Rates Selection Chart S2 2 S2 3 Asymmetric Line Rates DS US ON ON 50 Mbps 2 Mbps ON OFF 16 Mbps 2 Mbps OFF OFF 4 Mbps 1 Mbps Table 5 Ethernet configurations S2 4 S2 5 S2 6 Ethernet Configurations ON ON ON Auto Negotiate ON ON OFF 100Mb Full Duplex ON OFF ON 100Mb Half Duplex ON OFF OFF 10Mb Full Duplex OFF ON ON 10Mb Half Duplex ...

Page 16: ...ch setting to determine its Ethernet operating mode and Ethernet Shutdown mode configuration The S2 8 switch does not affect the data rate The data rate will always follow the L configuration 5 0 OPERATION Once the Model 2172s are properly installed they should operate trans parently No user settings required This section describes reading the LED status monitors 5 1 POWER UP Before applying power t...

Page 17: ...unit front panel Table 8 Front panel LED description LED Description Power Solid GREEN to indicate the unit is powered on Link Solid GREEN ON to indicate that the end to end CopperLINK link between the Model 2172s is estab lished The Link LED is OFF when the link is down Ethernet Solid GREEN indicates that 10 100Base T Ethernet link has been established Flashes to indicate activity Power LED Coppe...

Page 18: ...km at 1 Mbps upstream 4 Mbps downstream Note Distances depend on selected line rate and line conditions See Appendix D on page 21 for details A 4 COPPERLINK SURGE SUPPRESSOR SIDACTOR with maximum current surge 20 kA 8 20 μs A 5 LED STATUS INDICATORS Power Green CopperLINK Link Green Ethernet Link Green Activity Flashing Green A 6 POWER SUPPLY External AC and DC options AC 120 VAC 220 VAC and UI 12...

Page 19: ...hernet Extender Kit 2 units pre set to local and remote 110 240VAC 07M2172 UM User Manual Power Supplies 08055DCUI 08055 120 5 1 100 240VAC 5V reg DC 2A Universal Input Adapter 120 VAC 5V reg DC 1A Input Adapter 12V PSM 12 VDC Input Adapter 24V PSM 24 VDC Input Adapter 48V PSM 48 VDC Input Adapter Power Cords 0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power ...

Page 20: ...ACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection Terminal Block Figure 1 Model 2172 Terminal Block twisted pair line interface Ethernet Power Made in the USA RING TIP Rem Loc ...

Page 21: ...wire used Note DS downstream US upstream Symm Line Rate Distance in feet km Throughput at Max Distance 50 Mbps 800 0 25 km 48 25 Mbps 2 000 0 61 km 24 5 10 Mbps 4 000 1 22 km 10 Asymm Line Rate DS US Distance in feet km Throughput at Max Distance DS US 50 Mbps 2 Mbps 2 000 0 61 km 48 2 16 Mbps 2 Mbps 4 000 1 22 km 15 2 4 Mbps 1 Mbps 6 000 1 82 km 3 75 1 ...

Page 22: ..._______________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ ____...

Page 23: ..._______________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ ____...

Page 24: ...24 Copyright 2008 Patton Electronics Company All Rights Reserved ...