Using a browser to complete Model 6511RC configuration
65
Model 6511RC User Manual
3 • Configuring the Matrix Switch for operation
The following notation should be used for assigning timeslots:
– dash: (-), e.g., 1 – 4
– comma: (,), e.g., 1,4,9
– combo: 1-2,3,6-7
At this point you have defined the SDH channel composed of a selected E1 signal stream and a set of
timeslots within that E1. Now you must define the mid-plane channel to be correlated with the
SDH channel.
6.
In the first row, labeled
to H110(5)
, for the
H.110 number,
select the appropriate H.110 port number
from the drop-down menu
7.
In the first row, labeled
toH110(5)
, for
H.110 slots,
enter the timeslot numbers you wish to map
to
the
H.110 bus (
from
the E1).
8.
In the second row, labeled
fromH110(6),
select the appropriate H.110 port number from the drop-
down menu
9.
In the second row, labeled
fromH110(6),
for
H.110 slots,
enter the timeslot numbers you wish to map
from
the H.110 bus (
to
the E1).
10.
Click the
Define
button. The new mapping will appear at the bottom of the page in the
Defined
Mappings
table.
11.
Examine the
Defined Mappings table
to verify that your new mapping appears and was correctly entered
and recorded.
Examples for configuring DS0 mappings.
Three examples are provided:
•
Example 1—
For E1 port number 1:
-
map all 32 timeslots of the
received
E1 signal
to
H.110 port 1 timeslots 1-32
-
map all 32 timeslots of the
transmitted
E1 signal
from
H.110 port 1 timeslots 33-64
•
Example 2—
For E1 port number 2:
-
map all 32 timeslots of the
received
E1 signal
to
H.110 port 1 timeslots 65-96
-
map all 32 timeslots of the
transmitted
E1 signal
from
H.110 port 1 timeslots 97-128
•
Example 3—
For E1 port number 7
-
map all 32 timeslots of the E1
received
signal
to
H.110 port 4 timeslots 1-32
-
map all 32 timeslots of the E1
transmitted
signal
from
H.110 port 4 timeslots 33-64