background image

3080/V24

124001UA

i

P

ATTON

 E

LECTRONICS

 C

O

.

I

NSTALLATION

 A

ND

 O

PERATIONS

 M

ANUAL

PROPRIETARY NOTICE

The information contained herein is proprietary and confidential to Patton

 

Electronics Co.  Any reproduction or

redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is given by
Patton

 

Electronics Co.

WARRANTY NOTICE

WARRANTIES:  Patton

 

Electronics Co. (hereafter referred to as Patton) warrants that its equipment is free from any

defects in materials and workmanship.  The warranty period shall be two years from the date of shipment of
equipment.  Patton’s sole obligation under its warranty is limited to the repair or replacement of the defective
equipment, provided it is returned to Patton, transportation prepaid, within a reasonable period.  This warranty will not
extend to equipment subjected to accident, misuse, alterations or repair not made by Patton or authorized by Patton in
writing.

PUBLICATION NOTICE

This manual has been compiled and checked for accuracy.  The information in this manual does not constitute a
warranty of performance.  Patton reserves the right to revise this publication and make changes from time to time in the
content thereof.  Patton assumes no liability for losses incurred as a result of out-of-date or incorrect information
contained in this manual.

RADIO AND TV INTERFERENCE

The Patton MSDs generate and use radio frequency energy, and if not installed and used properly—that is, in strict
accordance with the manufacturer’s instructions—may cause interference to radio and television reception.  The Patton
MSDs have been tested and found to comply with the limits for Class A computing devices in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such
interference in a commercial installation.  However, there is no guarantee that interference will not occur in a particular
installation.  If the Patton MSDs do cause interference to radio or television reception, which can be determined by
disconnecting the cables, the user is encouraged to try to correct the interference by one or more of the following
measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or
plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on
different branches).

CE NOTICE

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the electromagnetic
Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A Certificate of
Compliance is available by contacting Technical Support.

SERVICE

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics.  All returns
must have a Return Materials Authorization number on the outside of the shipping container. This number may be
obtained from Patton Electronics Technical Support at:

tel:  (301) 975-1007;
email:  [email protected];
or, www:  http://www.patton.com.
NOTE:  Packages received without an RMA number will not be accepted.

Patton Electronics’ technical staff is also available to answer any questions that might arise concerning the installation
or use of your Patton MSDs.  Technical Support hours: 8AM to 5PM EST, Monday through Friday.

Copyright© 2000 Patton Electronics Co., All Rights Reserved

Summary of Contents for 3080/V24

Page 1: ...TAL SHARING DEVICE 3080 V24 CTS DSD 8 INSTALLATION AND OPERATIONS MANUAL Doc 124001UA Part 07M3080 A B An ISO 9001 Certified Company Copyright 2000 Patton Electronics Co All Rights Reserved August 23...

Page 2: ...ave been tested and found to comply with the limits for Class A computing devices in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable pr...

Page 3: ...ass A limits for noise emissions from a digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le present appareil numerique n emet pas de bruits...

Page 4: ...tch on Data Control SW29 5 6 2 4 Internal Baud Rates SW30 1 2 3 4 2 4 Fallback Clock Enable SW 30 6 2 5 Fallback Clocking From Sub Channel 6 SW30 1 2 3 2 5 Fallback Mode Selection SW30 5 2 5 TX Clock...

Page 5: ...Master Port clock pins 15 or 24 for TXC and 17 for RXC the internal clock generator or any Sub Channel 1 through 6 pins 15 or 24 for TXC and 17 for RXC Fallback Clocking In the event of loss of an ext...

Page 6: ...RTS Mode if RTS is held active RTS must become inactive When configured for Switch on Data Mode if continuous data transitions have triggered the Anti Stream logic the transitions must stop before th...

Page 7: ...he active interface lead RTS or DCD can be selected on an individual basis for each Sub channel selection of contention mode Data Transitions or Interface Lead activation is selected in Sub channel gr...

Page 8: ...hannel from accessing the Master Port Positive latching type switches are provided for each Sub Channel port for isolating or removing a streaming terminal The Sub Channel is activated by pushing the...

Page 9: ...Slow Blow fuses EXAMPLE United States of America set to 110VA The unit is supplied with a IEC power connector next to the voltage select switch plug the power cord into the connector until it is firml...

Page 10: ...the Appendix of this manual After the switch selection activity is completed re install the top cover BEFORE connecting to a AC power source Installation Select an appropriate location accessible to a...

Page 11: ...SW28 4 5 and 6 As shown below eight block sizes are provided to the user To disable anti streaming set SW29 3 to the OFF position The maximum block size is normally defined at the time of installatio...

Page 12: ...groups of 4 Sub Channels Set SW29 pos 5 to OFF if you want Sub channels 1 thru 4 set to switch on Data Transitions Set pos 5 to ON if you want them to be set to switch on Interface Lead SW29 pos 6 is...

Page 13: ...lback Mode Selection SW30 5 default ON If Fallback is required two modes are available via switch SW30 5 To fallback when the transitions from the primary clock source stop set SW30 5 to ON To fallbac...

Page 14: ...when a Sub Channel is set as a DTE The buffer will provide clock synchronization of the data from the Sub Channel to the Master Port for Tail Circuit operations The buffer is de activated when the Su...

Page 15: ...CE position away from the interface connector The port is always configured opposite to the interface that is to be connected to it When a port is selected as a DCE pin 9 and 10 test voltages are prov...

Page 16: ...he forced DTR DSR jumper JP6 JP14 for the appropriate Sub Channel will solve this problem The line is forced to 6V via an 100 resistor providing isolation to any driver that might be on the interface...

Page 17: ...om DCE Signal Ground common Data Carrier Detect from DCE Voltage Voltage Transmit Clock from DCE Receive Clock from DCE Data Terminal Ready from DTE External Transmit Clock from DTE 3080 V24 RS 423 Le...

Page 18: ...D Pin 20 DTR Switch Control Buffer 6v Pin 15 TXC Pin 17 RXC Pin 24 ETXC Pin 15 TXC Pin 17 RXC Pin 24 ETXC Clk In Clk Out Master RX Clock Selection Logic Master TX Clock Selection Logic Channel Port is...

Page 19: ...aster Port is a DCE Pin 2 TXD Pin 3 RXD Pin 3 RXD Pin 2 TXD Pin 4 RTS Pin 5 CTS Pin 6 DSR Pin 8 DCD Pin 4 RTS Pin 5 CTS Pin 6 DSR Pin 8 DCD Switch Control 6v Channel Port is a DCE 6v Clk In Clk Out Pi...

Page 20: ...vice Modes Scanning Mode Channels are continuously scanned for activity on a sequential basis Priority Mode Channels are simultaniously monitored channel one has highest access Sub Channel Interface E...

Page 21: ...rce Master Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Internal Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 Priority ON Scan OFF Normal ON 3 4 OFF Baud Rate Select Fallback Disabled ON Enabl...

Page 22: ...B 7622 Rickenbacker Drive Gaithersburg MD 20879 Sales 301 975 1000 Support 301 975 1007 Web Address www patton com...

Reviews: