3060/X21
109001UA
P
ATTON
E
LECTRONICS
C
O
.I
NSTALLATION
A
ND
O
PERATIONS
M
ANUAL
A-3
A
PPENDIX
P
N
-1
0
9
0
10 D
DC
E
D
T
E
SW7
SW8
SW9
SW10
SW11
SW12 SW13
SW14
SW15
SW16 SW17
SW18
SW19
SW20
SW21
SW22
SW23
SW24
Enabled = GREEN / Disabled = BLACK
Fallback Enabled = ON / Disabled = OFF
Priority = ON / Scan = OFF
Baud Rate Selection
Anti-Stream Enabled = ON / Disabled = OFF
No Data Timer
Anti-Stream Timer
"R" Broadcast = ON / Gated = OFF
System Clocking Source
Signal Gnd to Chassis Gnd = ON
ON
OFF
1
2
3
4
5
6
ON
OFF
1
2
3
4
5
6
ON
OFF
1
2
3
4
5
6
ON
OFF
1
2
3
4
5
6
Baud Rate Selection - SW21
6
ON
ON
ON
ON
OFF
OFF
OFF
OFF
5
ON
ON
OFF
OFF
ON
ON
OFF
OFF
4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Opt 1
384 00
192 00
9600
4800
2400
1200
600
Opt 2
448 00
224 00
112 00
5600
2800
1400
700
Opt 3
512 00
256 00
128 00
6400
3200
1600
800
Opt 4
576 00
288 00
144 00
7200
3600
1800
900
Opt 5
384000
192000
960 00
480 00
240 00
120 00
6000
Opt 6
448000
224000
112000
560 00
280 00
140 00
7000
Opt 7
512000
256000
128000
640 00
320 00
160 00
8000
Opt 8
576000
288000
144000
720 00
360 00
180 00
9000
Control Active
Anti-Stream
1 2 3 4 5 6
1 2 3 4 5 6
Po
rt
1
Po
rt
2
Po
rt
3
Po
rt
4
Po
rt
5
Po
rt
6
PWR S
R
No Data Timer SW23
1
ON
ON
OFF
OFF
2
ON
OFF
ON
OFF
Clk Count
16
64
256
2048
Port 6
Port 5
Port 4
Port 3
Port 2
Port 1
Master
ON
OFF
1
2
3
4
5
6
SW25
Sync = ON / Async = OFF
CHANNEL 6 CLOCK
CH6 Follows = ON / Forced Active = OFF
Control to Indicate Delay
C / I Broadcast = ON / Gated = OFF
Master C Output Follows = ON / Forced = OFF
Unused
Anti-Stream Timer SW22
6
ON
ON
ON
ON
OFF
OFF
OFF
OFF
5
ON
ON
OFF
OFF
ON
ON
OFF
OFF
4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Clk Count
1024
2048
4096
16K
64K
256K
1M
2M
Baud Rate Options SW21
3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
2
ON
ON
OFF
OFF
ON
ON
OFF
OFF
1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Option
1
2
3
4
5
6
7
8
System Clk Source SW22
3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
2
ON
ON
OFF
OFF
ON
ON
OFF
OFF
1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Clk Source
Master
Po rt 1
Po rt 2
Po rt 3
Po rt 4
Po rt 5
Po rt 6
Internal
C to I Delay SW 25
5
ON
ON
OFF
OFF
ON
ON
OFF
OFF
4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Clk Count
No Delay
0.5mS
1.0mS
2.0mS
4.0mS
8.0mS
16.0mS
32.0mS
6
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Fallback
ON
OFF
1
2
3
4
5
6
SW27
CH1
CH2
CH3
CH4
CH5
CH6
Switch on Control = ON
/ Data Trans = OFF
ON
OFF
1
2
3
4
5
6
SW26
CH1
CH2
CH3
CH4
CH5
CH6
Control /Indicate
Output Follows = ON
/ Forced = OFF
DC
E
D
T
E
DC
E
D
T
E
DC
E
D
T
E
DC
E
DT
E
DC
E
D
T
E
DC
E
D
T
E
Control /Indicate
Output Follows = ON
/ Forced = OFF