background image

B

7622 Rickenbacker Drive
Gaithersburg, MD  20879

Sales: 301 975-1000     Support: 301 975-1007
Web Address: www.patton.com

Summary of Contents for 3046/V24

Page 1: ...SERVICE MULTIPLEXER 3046 V24 3046 V35 CTS DDS MUX INSTALLATION AND OPERATIONS MANUAL Doc 138001UA Part 07M3046 A B An ISO 9001 Certified Company Copyright 2000 Patton Electronics Co All Rights Reserve...

Page 2: ...DATA SERVICE MULTIPLEXER 3046 V24 3046 V35 CTS DDS MUX INSTALLATION AND OPERATIONS MANUAL Doc 138001UA Part 07M3046 A B An ISO 9001 Certified Company Copyright 2000 Patton Electronics Co All Rights R...

Page 3: ...ave been tested and found to comply with the limits for Class A computing devices in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable pr...

Page 4: ...138001UA ii INSTALLATION AND OPERATIONS MANUAL PATTON ELECTRONICS CO 3046 ii...

Page 5: ...1 2 CHAPTER 2 SETUP AND INSTALLATION Power Connection 2 1 Factory Configuration Switch Settings 2 1 Disassembly 2 1 Installation 2 2 Push Buttons 2 2 LCD SYSTEM STATUS Display 2 3 Composite Link Confi...

Page 6: ...lected for sync or async operation The only requirement is that the channel be configured identically on either side of the circuit Channel Clocking Low Speed composite data rates of 9 6kbps 14 4kbps...

Page 7: ...stores the new configuration and sets all the channels and composite port to those values Current conditions set into the 3046 CTS DDS MUX are indicated on the LCD with an Asterisk Loopback Selection...

Page 8: ...Factory Configuration Switch Settings The 3046 CTS DDS MUX is configured prior to shipment with the switches set to the following default positions COMPOSITE if Low Speed SPEED 19 2 MODE 3 LP BK DIS...

Page 9: ...the current MODE selected for the COMPOSITE link Factory default for mode is 3 so the highest channel number will be CH6 if the configuration has not been modified The PAR push button cycles the secon...

Page 10: ...emote end of the link This Remote Digital Loopback command is indicated on the LCD in the Middle of the SYSTEM STATUS display as RDL SYSTEM STATUS SYNC RDL 1013A001 If any channel is looped back withi...

Page 11: ...ite SPEED from the SYSTEM STATUS display press the CHN push button once and the PAR push button until the following LCD display appears 1013X002 CH PARAM VAL COMP SPEED 19 2 All Displays Shown in Fact...

Page 12: ...ot Available Not Available Not Available 2 4 8 4 8 1 2 1 2 Not Available Not Available 3 2 4 1 2 1 2 1 2 1 2 1 2 Composite Speed 19 2K Mode CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 1 9 6 4 8 2 4 1 2 Not Availabl...

Page 13: ...m all channels to be looped back at the same time To select composite LP BK Remote Digital Loopback from the SYSTEM STATUS display press the CHN push button once and the PAR push button until the foll...

Page 14: ...unavailable in the current configuration an asterisk will not appear on any value for that particular mode Speed The Channel Speed parameter is used to set the baud rate of each individual channel Th...

Page 15: ...ess STR to configure the 3046 CTS DDS MUX or CHN and PAR to select additional configuration parameters Changing any Parameter value and pressing the STR for the channel port WILL cause loss of data fo...

Page 16: ...om the SYSTEM STATUS display press the CHN push button until the desired channel appears and the PAR push button until the following LCD display appears 1013A003 CH PARAM VAL CHn CTS DL 0M Press the V...

Page 17: ...to select the local loopback test function If loopback is enabled the data that arrives at the channel connector is looped back to the terminal to verify continuity of the data path to the 3046 CTS DD...

Page 18: ...V RT A D CTS J N T RD B A FG E DSR P TD A C RTS H DTR S TD B W AA TT B U Y TT A RT B X NN DB 25 RS 232 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Shield common Transmit Data fr...

Page 19: ...19 2K HS Sub channel Interface Channels RS 232 DB25 Female connectors Modem Interface Composite RS 232 DB 25 Female Connector or V 35 M34 Front Panel Indicators Power Send Data Receive Data Remote Dig...

Page 20: ...HN Button Loop PAR Button Loop 56K 64K Command Tree Typical Application DDS Network Sync Terminal Sync Terminal Async Terminal Async Terminal Sync Host Async Terminal Async Terminal DDS MUX T I M EDI...

Page 21: ...B 7622 Rickenbacker Drive Gaithersburg MD 20879 Sales 301 975 1000 Support 301 975 1007 Web Address www patton com...

Reviews: