4.2   CONNECTION TO THE TERMINAL DEVICE

The Model 2703 is wired as a DCE, and–when configured proper-

ly–supports communication with a wide variety of terminal (DTE)
devices.  Compatible interface standards include EIA-530 (RS-422),
CCITT X.21 and CCITT V.35.  

All interfaces are supported on a female UD-26 connector (a sub-

miniature 26-pin “D” connector designated the “alt A” in the EIA-232
Standard).  The various physical/electrical connections mentioned
above are achieved by changing the Model 2703’s DIP switch settings
and attaching different adapter cables.   

If you wish to construct your own terminal adapter cable, please

consult the pinout diagram in Appendix B.  If you wish to purchase a
terminal adapter cable specifically designed to work with the Model
2703, please refer to the specific Patton part numbers listed in
Appendix C.

4.3   CONNECTION TO THE POWER SOURCE

As described in Section 3.3, the Model 2703 is available with three

power supply options: two AC and one DC.  The two AC power supply
options (Standard and Universal) use a female IEC power cord inter-
face, for which Patton can supply various domestic and international
power cords.  Please refer to Appendix C for specific Patton part num-
bers when ordering power cords.  The DC power supply option uses a
3-pin terminal strip interface (Note: Please refer to the Model 2703
Service Manual for DC power supply wiring instructions).

13

5.0  OPERATION

Once the Model 2703 is properly configured and installed, it

should operate transparently.  This sections describes power-up, read-
ing the LED status monitors, and using the built-in loopback test
modes.  

5.1  POWER-UP

To apply power to the Model 2703, first be sure that you have read

Section 3.3, and that the unit has the proper voltage setting and fuse.

Failure to do so could result in damage to the unit and connected
equipment, and may constitute a fire hazard.  

Having checked the volt-

age setting, plug the AC power cord into both the Model 2703 and the
AC outlet.  Then Power-up the unit using the rear Power switch.  Note:
the “Power” LED should glow when power is applied to the unit.

5.2  LED STATUS INDICATORS

The Model 2703 features four front panel LEDs that indicate the

status of power, network connection, master clock and loopback test.
Figure 6 (below) shows the front panel location of each LED.
Following Figure 6 is a description of each LED’s function.

Power

Glows red when the Model 2703 is powered up.

Network

Glows green when the Model 2703 is receiving 
correctly encoded data from the line interface 
equipment.

Master Clock Glows green when the Model 2703 is 

configured as the master clock unit. 

Loop

Glows green when the Model 2703 is in 
loopback mode.

14

Figure 6. Model 2703 Front Panel

Summary of Contents for 2703

Page 1: ...USER MANUAL MODEL 2703 G 703 E1 Digital Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2703 I Doc 031041UI Revised 08 16 99 An ISO 9001 Certified Company...

Page 2: ...are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interfer ence will not occur in a particular installation If the M...

Page 3: ...evice 256 kbps 512 kbps or 1 024 Mbps connect to a 2 048 Mbps G 703 link The Model 2703 supports internal or network receive loop clocking Loopback test is built in and front panel LEDs monitor power...

Page 4: ...and S1 5 together to allow the Model 2703 to adapt to terminal devices that run at data rates less than 2 048 Mbps The network rate remains 2 048 Mbps regardless of the terminal rate adaptation setti...

Page 5: ...ER SETTINGS The Model 2703 s seven jumpers are located on the Network Interface Module PC board inside the unit To access the jumpers fol low these instructions 1 Insert a flat head screw driver into...

Page 6: ...Impedance On Off On 75 Ohm Opt optional setting all others are required for proper operation Jumper LK2 75 Ohm Receive Shield to Ground Connection This setting determines whether the shield of the 75...

Page 7: ...ed service personnel Contact Patton Electronics Technical support at http www patton com or sup port patton com 301 975 1007 for more information 4 0 INSTALLATION Once the Model 2703 is properly confi...

Page 8: ...option uses a 3 pin terminal strip interface Note Please refer to the Model 2703 Service Manual for DC power supply wiring instructions 13 5 0 OPERATION Once the Model 2703 is properly configured and...