Patton electronics 2703 User Manual Download Page 3

2.0  GENERAL INFORMATION 

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is warrant-
ed for One Year parts and labor.  If any questions or problems arise
during installation or use of this product, please do not hesitate to con-
tact Patton Electronics Technical Support at (301) 975-1007.

2.1  FEATURES

• Synchronous network data rate of 2.048 Mbps
• Four selectable terminal rates: 256 kbps, 512 kbps, 

1.024 Mbps and 2.048 Mbps

• Supports X.21/EIA-530 (RS-422) and V.35 terminal interfaces
• Both 75 ohm (BNC) and 120 ohm (modular) network terminations
• Internal or receive loop (network) clocking
• Loopback test modes
• Front panel LED indicators for power, network,

master clock and test loop

2.2  DESCRIPTION

The Patton Model 2703 G.703/E1 Digital Modem performs sev-

eral jobs:  As a 

modem

, the Model 2703 receives unstructured, syn-

chronous 2.048 Mbps data from a G.703 network and sends it to a
router, bridge, multiplexer or other device.  As an 

interface converter

,

the Model 2703 accepts 120 Ohm twisted pair or 75 Ohm dual coax
network connections (both types of interfaces provided).  Then it con-
verts the signals to X.21/EIA-530 (RS-422) or V.35 (switchable) on an
UD-26 connector. 

As a 

Rate Adapter

, the Model 2703 lets a lower bandwidth

device–256 kbps, 512 kbps, or 1.024 Mbps–connect to a 2.048 Mbps
G.703 link.  The Model 2703 supports internal or network (receive
loop) clocking.  Loopback test is built-in, and front panel LEDs monitor
power, network, master clock and test loop.  Several power supply
options are available.

3

3.0  CONFIGURATION

The Model 2703 is equipped with two sets of eight DIP switches

(externally accessible), as well as seven jumpers (internal).  These DIP
switches and jumpers allow configuration of clocking, data rate, test
and terminal interface options. The Model 2703 is also equipped with
an internal switch that allows selection of 115 or 230 VAC power inputs
(Note: this switch is not present in Models 2703-UI and 2703-DC).
This section describes switch and jumper locations and explains all
possible configurations.

3.1  EXTERNAL DIP SWITCH SETTINGS

The Model 2703’s DIP switches are located on the underside of

the unit (see Figure 1, below).  Figure 2 (below), shows the orientation
of the switch set.  All possible settings for the Model 2703’s DIP
switches are presented in the summary table and descriptions on the
following pages. The switches are grouped into two eight-switch sets,
and are externally accessible from the underside of the Model 2703
(See Figure 1).   

4

Figure 2. Close up of configuration switches 

OFF

1 2 3 4 5 6 7 8

DHS-8

OFF

ON

Figure 1. Underside of Model 2703, showing external DIP switch locations

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

Switch

Set “S1”

Switch

Set “S2”

1     2     3     4     5     6     7     8

O N

ON

OFF

Summary of Contents for 2703

Page 1: ...USER MANUAL MODEL 2703 G 703 E1 Digital Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2703 I Doc 031041UI Revised 08 16 99 An ISO 9001 Certified Company...

Page 2: ...are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interfer ence will not occur in a particular installation If the M...

Page 3: ...evice 256 kbps 512 kbps or 1 024 Mbps connect to a 2 048 Mbps G 703 link The Model 2703 supports internal or network receive loop clocking Loopback test is built in and front panel LEDs monitor power...

Page 4: ...and S1 5 together to allow the Model 2703 to adapt to terminal devices that run at data rates less than 2 048 Mbps The network rate remains 2 048 Mbps regardless of the terminal rate adaptation setti...

Page 5: ...ER SETTINGS The Model 2703 s seven jumpers are located on the Network Interface Module PC board inside the unit To access the jumpers fol low these instructions 1 Insert a flat head screw driver into...

Page 6: ...Impedance On Off On 75 Ohm Opt optional setting all others are required for proper operation Jumper LK2 75 Ohm Receive Shield to Ground Connection This setting determines whether the shield of the 75...

Page 7: ...ed service personnel Contact Patton Electronics Technical support at http www patton com or sup port patton com 301 975 1007 for more information 4 0 INSTALLATION Once the Model 2703 is properly confi...

Page 8: ...option uses a 3 pin terminal strip interface Note Please refer to the Model 2703 Service Manual for DC power supply wiring instructions 13 5 0 OPERATION Once the Model 2703 is properly configured and...

Page 9: ...s operating properly and can be used for a test If a fault is indicated call a tech nician or replace the unit C Perform a BER bit error rate test on each unit If the BER test equipment indicates no f...

Page 10: ...r cord which must be specified in the model number when ordering The DC version is supplied without a power cord All versions of the Model 2703 are supplied without a terminal DTE interface cable This...

Page 11: ...permission to attach Any other usage will invalidate the approval of the Interface Module Interconnection of the Interface Module the port marked Network directly or by way of any other apparatus wit...