4.3  POWER CONNECTION

The Model 2094 offers three  ways to supply external power:  AC

power, DC power and interface power.  

4.3.1  Using the AC Power Supply (100-240VAC)

The Model 2094 uses a 5VDC, 2A universal input 100-240VAC,

power supply (center pin is +5V).  The universal input power supply is
equipped with a male IEC-320 power entry connector.  This power sup-
ply connects to the Model 2094 by means of a barrel jack on the rear
panel.  There are a variety of international power cords available for
the universal power supply.  The Model 2094 powers up as soon as it
is plugged into an AC outlet–there is no power switch.  

4.3.2  Supplying DC Power 

The 36-60 VDC DC to DC adapter is supplied with the DC version

of the Model 2094.  The black and red leads plug into a DC source
(nominal 48VDC) and the barrel power connector plugs into the barrel
power supply jack on the 2094

.  

4.3.3  Supplying Power via pin KK

You may also supply DC power directly to pin KK of the V.35 inter-

face.  DC Power supplied to pin KK must be +5VDC ± 5%, 300mA
minimum.

NOTE: Model 2094 is factory configured to accept power from the
enclosed DC wall adapter (See Sections 4.3.1 and 4.3.2 above).
If you wish to supply power via pin KK on the interface, you must
change the setting of the

power supply jumper on the printed cir-

cuit board  See Appendix E.   All power sources must be SELV
(Circuit, Safety Extra Low Voltage) specified.  (See CENELEC
EN60950, Section 1.2.8.5)

5.0  OPERATION

Once the Model 2094 is installed and configured properly it is ready

to place into operation.  This section describes the function of the LED
indicators, and the use of the loopback and pattern test modes.

5.1  LED DESCRIPTIONS

The Model 2094 is equipped with seven LED indicators that moni-

tor the status of communication.  Figure 4 (below) shows the location
of the LEDs on the Model 2094  front panel. 

TXD

When the unit sends a one, the TXD LED is
turned on. When it sends a zero, the TXD
LED is turned off. Moreover, the TXD LED
is active only in active DS0 channels. In
inactive channels, the TXD LED is off.

RXD

When the unit receives a one, the RXD LED
is turned on. When it receives a zero, the
RXD LED is turned off. Moreover, the RXD
LED is active only in active DS0 channels.
In inactive channels, the RXD LED is off.

RXD

LOS

ALM

ERR

T/L

PWR

TXD

Model 2711

Figure 4.  Top of Model 2094, Showing LED Indicators

Model2094

To Power

Supply Jack

To -48VDC

Source

-Vin

+Vin

SWITCHING POWER SUPPL

Y

MODEL

 : SYD1

106-0505

INPUT

 : 36-60V      0.2A

 MAX

OUTPUT

 : +5V       1.0A

OUTPUT

 POWER : 5W MAX

S/N

: G01234567890

                             

MADE IN CHINA

 BY

 SUNNY

Black lead (-V)

Red lead (+V)

Barrel power connector

Summary of Contents for 2094

Page 1: ..._________________________________ __________________________________________ __________________________________________ __________________________________________ _____________________________________...

Page 2: ...arts and labor If any questions or problems arise during installation or use of this product please do not hesitate to con tact Patton Electronics Technical Services at 301 975 1007 1 1 WARRANTY STATE...

Page 3: ...Model 2094 has been tested and found to com ply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide...

Page 4: ...o the V 35 DTE interface of a router switch FRAD multiplexer or other network ing device The Model 2094 supports all necessary G 703 G 704 diagnostics DTE local remote loops and V 54 loop up loop down...

Page 5: ...s all possible hardware and software switch configurations of the Model 2094 3 1 DIP SWITCH CONFIGURATION The Model 2094 has eight internal DIP switches that allow configu ration for a wide range of a...

Page 6: ...e upper four bits The alignment word is always 0000 binary The 2094 does not perform any signaling in TS16 other than to insert the MF alignment word in order to maintain MF alignment When CAS MF is d...

Page 7: ...nabled 3 Here is an example of a terminal emulator setup session In normal font are the various parameter types In bold type are the values that should be used for best results Your terminal program s...

Page 8: ...or the network performance initiate V 54 loops local loops and send test patterns Network performance parameters are updated once a second giving you the ability to quickly deter mine if there is a pr...

Page 9: ...os This method enables the net work to meet minimum pulse density requirements Unless AMI is required in your application HDB3 should be used whenever possible AMI Alternate Mark Inversion defines a p...

Page 10: ...64kb s timeslots num bered 0 to 31 TS16 of the first frame in the MF contains the CAS MF alignment word in the upper four bits The alignment word is always 0000 binary The 2094 does not perform any si...

Page 11: ...e the unit to use the DIP switches as the default configuration source by turning off the unit set ting all the DIP switches to the ON position then powering on the unit This will cause the unit to en...

Page 12: ...en sends an all ones pattern before returning to the Idle state TxP The Model 2094 is sending a test pattern while in Test Mode IdlP The Model 2094 is sending a test pattern in place of data The Model...

Page 13: ...ault Header Line 1 Header Line 2 Headers 1 and 2 are provided for easy identification of your unit after installation You may want to give each unit a unique name via the header lines to help distingu...

Page 14: ...r interfaces This section briefly describes connection to each 4 1 DTE INTERFACE CONNECTION The DTE interface is a V 35 DCE presented as an M 34 male connec tor This interface is designed to plug dire...

Page 15: ...in KK on the interface you must change the setting of the power supply jumper on the printed cir cuit board See Appendix E All power sources must be SELV Circuit Safety Extra Low Voltage specified See...

Page 16: ...st the NTU and any communication links These tests can be activated via the software control port See Section 3 2 3 System Diagnostics or via signals on the serial port interface 5 2 1 Operating Local...

Page 17: ...or 2 20 bits respectively using a mathematical polynomial The receiving model 2904 then decodes the received bits using the same polynomial If the received bits match the agreed upon pseudo random pat...

Page 18: ...C Dimensions 9 0 x 5 3 x 2 0 cm 3 5 L x 2 1 W x 0 78 H APPENDIX B PATTON MODEL 2094 CABLE RECOMMENDATIONS The Patton Model 2094 has been performance tested by Patton technicians using twisted pair ca...

Page 19: ...ale UI 10 09F 6 Foot Control Port Cable 25 mm to DB9F 08055DCUI Universal Input Power Supply 10 CISCO V35FT 1 Cable V35 M 34 Female To LFH60 Male 07M2094 User Manual APPENDIX D PATTON MODEL 2094 INTER...

Page 20: ...ock DCE Source AA TC Transmitter Clock DCE Source KK Aux Power Input 5VDC 300mA APPENDIX E PATTON MODEL 2094 POWER SUPPLY INTERFACE Via Main 5VDC power jack J1 Center Pin 5VDC 300 mA Outer Barrel Grou...

Reviews: