Switch SW2.2 DS0 Channel Rate

This switch is used to set the DS0 rate in framed modes; in

unframed mode, this switch is used with SW2.1 to set the clocking
mode.

SW2.2

DS0 Rate

Off

56 kbps

On

64 kbps

Switch SW2.1 Clock Mode

This switch is used to select the timing source for transmitting data

to the T1 port.  External clocking is available only in unframed mode
(DTE data rate of 1544 kbps). 

NOTE: When using the Model 2090 to terminate a T1 port, the 2090 

must be set to network clock.  When using the Model 2090 as
a high-speed short range modem, one unit of the link must be
configured for Internal Clock mode, and the unit on the oppo
site end must be configured for Network Clock mode.

Function

SW2.2

SW2.1

Clocking Mode

Don’t Care

Off

Network

Don’t Care

On

Internal

Don’t Care

Off

Network

Off  

On

Internal

On

On

External

CLOCKING AND FRAMING MODES

Framed Mode (ESF/D4)

Unframed Mode

13

4.0  INSTALLATION

The Model  2090 is equipped with a DTE,  network, and power

interface.  This section briefly describes connection to each.

4.1  DTE INTERFACE CONNECTION

The DTE interface is a V.35 DCE presented as an M/34 male con-

nector.  This interface is designed to plug directly into a DTE interface
(See Appendix D for V.35 interface pin assignments).

4.2  NETWORK INTERFACE CONNECTION

The Network Line Interface is an eight position keyed modular jack

configured as a RJ-48C.  This interface will need to be configured to
match the line parameters  (i.e. framing, line coding) supplied by the
connected equipment.

NOTE:  If the Model 2090 Series is being used for private short
range modem applications, the twisted pair cable connected to its
port will need to be a cross-over cable.  See Appendix D for
Interface pin assignments.

4.3  POWER CONNECTION

The Model 2090 Series is powered via a supplied external trans-

former and is factory configured for either 120VAC or 100-240VAC
operation.  This connection is via the barrel jack on the rear of the
2090.  The Model 2090 can also be powered via the DTE interface
when supplied with +5VDC @ 300mA to Pin KK.  See Appendix D for
more information.

DC Power Supply

The 36-60 VDC DC to DC adapter is supplied with the DC version of
the Model 2090.  The black and red leads plug into a DC source (nomi-
nal 48VDC) and the barrel power connector plugs into the barrel power
supply jack on the 2090

.

To Power

Supply Jack

To -48VDC

Source

-Vin

+Vin

SWITCHING POWER SUPPL

Y

MODEL

 : SYD1

106-0505

INPUT

 : 36-60V      0.2A

 MAX

OUTPUT

 : +5V       1.0A

OUTPUT

 POWER : 5W MAX

S/N

: G01234567890

                             

MADE IN CHINA

 BY

 SUNNY

Black lead (-V)

Red lead (+V)

Barrel power connector

Summary of Contents for 2090 Series

Page 1: ...Part 07M2090 UM Doc 07729U2 001 Rev D Revised 10 25 06 C E R T I F I E D An ISO 9001 Certified Company APPENDIX E PATTON MODEL 2090 SERIES POWER SUPPLY INTERFACE Main 5VC power jack J1 Center Pin 5VDC...

Page 2: ...rranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification This product contains no serviceable parts therefore the user shall not a...

Page 3: ...is encouraged to try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the...

Page 4: ...ly to T1 FT1 The Model 2090 Series is easily configurable using pc board mounted DIP switches Use the DIP switches to set D4 and ESF framing modes AMI or B8ZS line coding clocking modes Line Build Out...

Page 5: ...llow you to specify data rates line framing and coding DSO rate clock mode and Line Build Out LBO Factory default settings of all switches are shown in the table below In unframed mode SW2 2 is used w...

Page 6: ...2 For unframned operation 1544 kbps set SW1 8 SW1 7 SW1 6 SW1 5 SW1 4 to OFF Switches SW1 1 SW1 2 SW1 3 SW 2 7 SW2 8 These switches set the starting channel The starting channel is the first channel...

Page 7: ...ires one of two methods Reduce the rate of each time slot DS0 to 56 kbps so that the last bit can be used to guarantee the minimum ones density Or make sure that the DTE sends data in such a way that...

Page 8: ...a DTE interface See Appendix D for V 35 interface pin assignments 4 2 NETWORK INTERFACE CONNECTION The Network Line Interface is an eight position keyed modular jack configured as a RJ 48C This interf...

Page 9: ...There are several flash ing patterns to indicate the type of error Invalid Switch Configuration It is possible to request more bandwidth than is possible For instance if you set the starting channel...

Page 10: ...ramer portion of the converter The 2090 will respond to Universal Loopback Deactivate to clear all central office loops APPENDIX A PATTON MODEL 2090 SERIES SPECIFICATIONS WAN Speed 1 544 Mbps WAN Conn...

Page 11: ...e twisted pair wire this is not an option Use twisted pair wire with a capacitance of 20pf ft or less Avoid twisted pair wire thinner than 26 AWG i e avoid higher AWG numbers than 26 Use of twisted pa...

Page 12: ...GND Earth Ground Shield B SGND Signal Ground D CTS DCE Source E DSR DCE Source Always On F CD DCE Source L LL Local Loop DTE Source M TM Test Mode Indicators DCE Source N RL Remote Loop DTE Source P...

Reviews: