3

1.3  RADIO AND TV INTERFERENCE

The Model 2090 Series generates and uses radio frequency energy,

and if not installed and used properly—that is, in strict accordance with
the manufacturer's instructions—may cause interference to radio and
television reception.  The Model 2090 Series has been tested and found
to comply with the limits for a Class A computing device in accordance
with the specifications in Subpart J of Part 15 of FCC rules, which are
designed to provide reasonable protection from such interference in a
commercial installation.  However, there is no guarantee that interference
will not occur in a particular installation.  If the Model 2090 Series does
cause interference to radio or television reception, which can be determined
by disconnecting the cables, the user is encouraged to try to correct
the interference by one or more of the following measures:  moving the
computing equipment away from the receiver, re-orienting the receiving
antenna, and/or plugging the receiving equipment into a different AC
outlet (such that the computing equipment and receiver are on different
branches).

4

1.4  SERVICE

All warranty and non-warranty repairs must be returned freight

prepaid and insured to Patton Electronics.  All returns must have a
Return Materials Authorization number on the outside of the shipping
container. This number may be obtained from Patton Electronics
Technical Support at: 

telephone:  (301) 975-1007
email:  [email protected]
web address: http://www.patton.com

NOTE: Packages received without an RMA number will not be
accepted.

Patton Electronics' technical staff is also available to answer any

questions that might arise concerning the installation or use of your
Patton Model  2090.  Technical Service hours:  8AM to 5PM EST,
Monday through Friday.

Summary of Contents for 2090 Series

Page 1: ...Part 07M2090 UM Doc 07729U2 001 Rev D Revised 10 25 06 C E R T I F I E D An ISO 9001 Certified Company APPENDIX E PATTON MODEL 2090 SERIES POWER SUPPLY INTERFACE Main 5VC power jack J1 Center Pin 5VDC...

Page 2: ...rranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification This product contains no serviceable parts therefore the user shall not a...

Page 3: ...is encouraged to try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the...

Page 4: ...ly to T1 FT1 The Model 2090 Series is easily configurable using pc board mounted DIP switches Use the DIP switches to set D4 and ESF framing modes AMI or B8ZS line coding clocking modes Line Build Out...

Page 5: ...llow you to specify data rates line framing and coding DSO rate clock mode and Line Build Out LBO Factory default settings of all switches are shown in the table below In unframed mode SW2 2 is used w...

Page 6: ...2 For unframned operation 1544 kbps set SW1 8 SW1 7 SW1 6 SW1 5 SW1 4 to OFF Switches SW1 1 SW1 2 SW1 3 SW 2 7 SW2 8 These switches set the starting channel The starting channel is the first channel...

Page 7: ...ires one of two methods Reduce the rate of each time slot DS0 to 56 kbps so that the last bit can be used to guarantee the minimum ones density Or make sure that the DTE sends data in such a way that...

Page 8: ...a DTE interface See Appendix D for V 35 interface pin assignments 4 2 NETWORK INTERFACE CONNECTION The Network Line Interface is an eight position keyed modular jack configured as a RJ 48C This interf...

Page 9: ...There are several flash ing patterns to indicate the type of error Invalid Switch Configuration It is possible to request more bandwidth than is possible For instance if you set the starting channel...

Page 10: ...ramer portion of the converter The 2090 will respond to Universal Loopback Deactivate to clear all central office loops APPENDIX A PATTON MODEL 2090 SERIES SPECIFICATIONS WAN Speed 1 544 Mbps WAN Conn...

Page 11: ...e twisted pair wire this is not an option Use twisted pair wire with a capacitance of 20pf ft or less Avoid twisted pair wire thinner than 26 AWG i e avoid higher AWG numbers than 26 Use of twisted pa...

Page 12: ...GND Earth Ground Shield B SGND Signal Ground D CTS DCE Source E DSR DCE Source Always On F CD DCE Source L LL Local Loop DTE Source M TM Test Mode Indicators DCE Source N RL Remote Loop DTE Source P...

Reviews: