4.0  INSTALLATION

The Patton Model 2035 is very simple to install.  Once you have

configured the DIP switches, just plug it in like a normal cable and
you're ready to go.  Figure 3 illustrates the proper connections for the
standard cables.  If you have special-ordered a non-standard
connector, your connections may be different.

5.0  OPERATION

Once your interface converter is properly configured and installed,

it should operate transparently—as if it were a standard cable
connection.  Operating power is derived from the RS-232 data and
control signals; there is no “ON/OFF” switch.  

5.1  LED  STATUS MONITORS

The Model 2035 features an easy-to-read status LED that glows

red to indicate the condition of the transmission line.  Figure 1 shows
the location of the LED.  The following chart describes the LED's
various functions.

The red LED indicator blinks to show data activity.  However, since

there is only one indicator, it uses different LED codes to demonstrate
various messages.  The following chart describes these codes:

7

8

LED Codes

●  ●  

●  

———

●  ●  

●  

———

Computer is sending data

●  

———

●  

———

●  

———

Serial device is connected; computer is 

not sending data

●  ●  

———

●  ●  

———

Both serial and parallel devices are

connected; computer not sending
data

●  

●  

———

●  

●  

———

Printer not ready, data held in buffer

●  ●  ●  ●  

———

●  ●  ●  ●

Computer ignoring flow control, data lost

Key:

Blink

Short pause

———

Long pause

Figure 3.  Installing the Model 2035

Model 2035

PC

Printer

Summary of Contents for 2035-25M

Page 1: ...35 25M Parallel to Serial Serial to Parallel Interface Converters SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2035 B Doc 102051UB Revised 6 27 97 C E R T I F I...

Page 2: ...which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If...

Page 3: ...75 1007 http www patton com or support patton com 2 1 FEATURES Converts parallel data to serial data and vice versa Automatic parallel and serial sensing and selection Automatic DCE DTE sensing and se...

Page 4: ...ncy and Data Rate Switches 6 through 8 determine the frequency and data rate The following chart shows the settings that may be used 6 1 200 OFF OFF ON 2 400 ON OFF ON 4 800 ON ON OFF 9 600 OFF ON ON...

Page 5: ...5 1 LED STATUS MONITORS The Model 2035 features an easy to read status LED that glows red to indicate the condition of the transmission line Figure 1 shows the location of the LED The following chart...

Page 6: ...Output 2 Data bit 0 3 Data bit 1 4 Data bit 2 5 Data bit 3 6 Data bit 4 7 Data bit 5 8 Data bit 6 9 Data bit 7 10 Acknowledge Input active low 11 Busy Input active high 12 Paper end 13 Select 18 5 vo...

Page 7: ...Sales E mail sales patton com Support E mail support patton com Phone Sales 301 975 1000 Phone Support 301 975 1007 Fax 301 869 9293 Mail Patton Electronics Company 7622 Rickenbacker Drive Gaithersbu...