3.2  DETAILED SWITCH SETTINGS

This section provides detailed information about the function of

each DIP switch and lists all possible settings.

Switch 1:  Hardware/Software Control

The setting for Switch 1 determines whether these interface

converters will control either hardware or software flow control.

Switch 2:  Used to Enable/Disable the LED Indicator

The setting for Switch 2 determines whether the LED indicator is

enabled or disabled.

5

Switch 3 through 5:  Data, Parity and Stop Bit

Switches 3 through 5 are used to specify the data, parity and stop

bits.  The following table shows the settings that may be used:

Switches 6 through 8:  Frequency and Data Rate

Switches 6 through 8 determine the frequency and data rate.  The

following chart shows the settings that may be used.

6

1,200

OFF

OFF

ON

2,400

ON

OFF

ON

4,800

ON ON

OFF

9,600

OFF

ON

ON

19,200

ON

ON

ON

38,400

OFF

OFF

OFF

57,600

ON

OFF

OFF

115,200

OFF

ON

OFF

Data Rate

SW6

SW7

SW8

Flow Control SW1
Hardware

OFF

Software

ON

LED

SW2

Enabled

ON

Disabled

OFF

7B

EP

1S

ON

ON

ON

7B

OP

1S

OFF

ON

ON

7B

NP

2S

ON

OFF

ON

7B

EP

2S

OFF

OFF

ON

7B

OP

2S

ON

ON

OFF

8B

EP

1S

OFF

ON

OFF

8B

OP

1S

ON

OFF

OFF

8B

NP

1S

OFF

OFF

OFF

Stop

Data

Parity

Bit

SW3

SW4

SW5

DIP SWITCH SUMMARY TABLE

Position

Function

Factory Default

SW1

Flow Control

Off

SW2

LED Indicator

On

SW3

Data, Parity, Stop Bits

Off

SW4

Data, Parity, Stop Bits

Off

SW5

Data, Parity, Stop Bits

Off

SW6

Data Rate

Off

SW7

Data Rate

Off

SW8

Data Rate

Off

Hardware

Enabled

8B, NP, 1S

38400 bps

}

}

Summary of Contents for 2035-25M

Page 1: ...35 25M Parallel to Serial Serial to Parallel Interface Converters SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2035 B Doc 102051UB Revised 6 27 97 C E R T I F I...

Page 2: ...which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If...

Page 3: ...75 1007 http www patton com or support patton com 2 1 FEATURES Converts parallel data to serial data and vice versa Automatic parallel and serial sensing and selection Automatic DCE DTE sensing and se...

Page 4: ...ncy and Data Rate Switches 6 through 8 determine the frequency and data rate The following chart shows the settings that may be used 6 1 200 OFF OFF ON 2 400 ON OFF ON 4 800 ON ON OFF 9 600 OFF ON ON...

Page 5: ...5 1 LED STATUS MONITORS The Model 2035 features an easy to read status LED that glows red to indicate the condition of the transmission line Figure 1 shows the location of the LED The following chart...

Page 6: ...Output 2 Data bit 0 3 Data bit 1 4 Data bit 2 5 Data bit 3 6 Data bit 4 7 Data bit 5 8 Data bit 6 9 Data bit 7 10 Acknowledge Input active low 11 Busy Input active high 12 Paper end 13 Select 18 5 vo...

Page 7: ...Sales E mail sales patton com Support E mail support patton com Phone Sales 301 975 1000 Phone Support 301 975 1007 Fax 301 869 9293 Mail Patton Electronics Company 7622 Rickenbacker Drive Gaithersbu...

Reviews: