4.0  INSTA L L AT I O N

The Model 2017A is simple to install.  After configuring the

DCE/DTE and active/passive switches, connect the two twisted pairs
using the following instructions.

4.1

TWISTED PAIR WIRING OVERVIEW

Only one Model 2017A is needed for each RS-232 to 20mA cur-

rent loop circuit.  The Model 2017A is connected to the current loop
device using two twisted pairs.  The pairs must be dry, unconditioned
metallic wire, 19-26 AWG.  Best distance is achieved with smaller
gauges (i.e., thicker wires).  When you have completed wiring for your
data circuit, the pin connections should be as shown below:

4.1.1

TWISTED PAIR CONNECTION USING TERMINAL BLOCKS

The terminal block/strain relief version of the Model 2017A allows

you to hook up the line side interface using bare wires.  The following
instructions will tell you how to open the case, connect the bare wires,
and fasten the strain relief collar in place.

1.  Open the unit by gently inserting a screw driver between the

DB-25 connector and the lip of the plastic case (see below).  You don't
have to worry about breaking the plastic, but be careful not to bend the
D-sub connector.

Once the unit has been opened, you will be able to see the termi-

nal blocks located at the rear of the PC board.   

2.  Strip the outer insulation from the twisted pairs about one inch

from the end.  

3.  Strip back the insulation on each of the 2 twisted pair wires

about .25".

4.  Connect one pair of wires in the telephone cable to "XMT"

(Transmit) on the terminal block, being careful to observe the polarity.
(The wire connected to "XMT+" must be connected at the other end of
the telephone line to "RCV+" in the other unit and the wire connected
to "XMT-" must be connected at the other end of the telephone line to
"RCV-" in the other unit).

5. Connect the other pair of wires in the telephone cable to "RCV"

(Receive), again being careful to observe the polarity.  (The wire con-
nected to "RCV+" must be connected at the other end of the telephone
line to "XMT+" in the other unit and the wire connected to "RCV-" must
be connected at the other end of the telephone line to "XMT-" in the
other unit).

5

6

XMT +

RCV+

XMT -

RCV -

G

G

RCV -

XMT -

RCV +

XMT +

To Shield (Optional)

}

One Pair

}

One Pair