1 2 0 6 P
I
NSTALLATION
A
ND
O
PERATIONS
M
ANUAL
1 1 8 0 0 1 U A
P
ATTON
E
LECTRONICS
C
O
.
2-3
S
ETUP
& I
NSTALLATION
Selection of internal rates is provided by configuration of SW1 positions 1 through 4 and JP7
through JP10 if the High Speed Option has been installed by the factory. The following table
shows the rates available:
SW1-1
SW1-2
SW1-3
SW1-4
RATE
ON
ON
ON
ON
HS Opt
OFF
ON
ON
ON
768K
ON
OFF
ON
ON
384K
OFF
OFF
ON
ON
192K
ON
ON
OFF
ON
128K
OFF
ON
OFF
ON
72K
ON
OFF
OFF
ON
64K*
OFF
OFF
OFF
ON
57.6K
ON
ON
ON
OFF
56K
OFF
ON
ON
OFF
48K
ON
OFF
ON
OFF
38.4K
OFF
OFF
ON
OFF
28.8K
ON
ON
OFF
OFF
19.2K
OFF
ON
OFF
OFF
14.4K
ON
OFF
OFF
OFF
9.6K
OFF
OFF
OFF
OFF
4.8K
High Speed Option Rates (JP7,JP8,JP9,JP10)
If the high speed option is installed the following rates can be utilized by setting SW1 positions
1 through 4 to
ON
:
JP10 Installed JP7, JP8 & JP9 Removed - 256K
JP9 Installed JP7, JP8 & JP10 Removed - 512K
JP8 Installed JP7, JP9 & JP10 Removed - 1.024M
JP7 Installed JP8, JP9 & JP10 Removed - 2.048M
Factory Test Jumper (JP1)