Caution, Disconnect the POWER Before Removing The Cover

Vorsicht, Befor Deckung Abnehmen Mach Strom Zu.

Power Connection

Before connecting the 1206P (CTS ME-X.21) to a AC power source the top cover must be
installed and secured with the supplied #8-32 screws.  The unit is supplied with a 110/220VA
voltage switch, turn the switch with a coin or screw driver to the appropriate voltage for your
country.  EXAMPLE: In the United States of
America; set to 110VA.  The unit is supplied
with a IEC power connector next to the
voltage select switch, plug the power cord
into the connector until it is firmly seated.
You may now connect the power cord into
your AC outlet.

Factory Configuration Switch Settings

The 1206P (CTS ME-X.21) is configured prior to shipment with the switches set to the
following default positions:

Switch 1 - 2, 3, 5 and 6 to 

OFF

, 1 and 4 to 

ON

.

Baud Rate = 64Kbps

Switch 2 - 1, 3, 4 and 6 to 

OFF

, 2, and 5 to 

ON

.

Port 1 IND Delay = 0
Port 2 IND Delay = 0

JP1 - JP3 always connected
JP4
 - Open

HS Option

JP7 - Open
JP8  - Open
JP9  - Open
JP10  - Open

If the system application requires one of more of the  default settings to be
changed, it will be necessary to remove the top cover of the enclosure to access
and change the DIP switches or Jumpers located on the printed circuit board.

CHAPTER 2 - S

ETUP

 

AND

  I

NSTALLATION

CAUTION

:   F O R   C O N T I N U E D   P R O T E C T I O N   A G A I N S T   R I S K  

F I R E ,   R E P L A C E   O N L Y
W I T H   S A M E   T Y P E
A N D   R A T I N G   F U S E .

110  / 220 VA  S witch

Fuse Drawer

P O R T   1

IEC Power Connector

110

220

100-120V

0.16ASB,250V

TO.16A,250V

200-240V

0.08ASB,250V

TO 0.08A,250V

 *

 

Switch fuse for 100-120V (.16ASB, 250V) or 200-240V

(.8ASB, 250V) as noted on rear of unit.

Summary of Contents for 1206P

Page 1: ...MODEM ELIMINATOR X 21 1 2 0 6 P CTS ME X 21 INSTALLATION AND OPERATIONS MANUAL Doc 118001UA Part 07M1206P A Copyright 2000 Patton Electronics Co All Rights Reserved An ISO 9001 CertifiedCompany...

Page 2: ...anty period shall be two years from the date of shipment of equipment Patton s sole obligation under its warranty is limited to the repair or replacement of the defective equipment provided it is retu...

Page 3: ...adiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residentia...

Page 4: ...R 2 SETUP AND INSTALLATION Power Connection 2 1 Factory Configuration Switch Settings 2 1 Disassembly 2 2 Installation 2 2 Equipment Grounding JP4 2 2 IND Delay Port 1 SW2 1 2 2 2 IND Delay Port 2 SW2...

Page 5: ...gh Speed Option are provided by the internal baud rate generator The generator will provide clocks for both terminal and insure the data is synchronized with the S Clock in both directions Delaying IN...

Page 6: ...in your data center CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive L...

Page 7: ...t Factory Configuration Switch Settings The 1206P CTS ME X 21 is configured prior to shipment with the switches set to the followingdefaultpositions Switch 1 2 3 5 and 6 to OFF 1 and 4 to ON Baud Rate...

Page 8: ...uld be used to connect the two terminals to the 1206P CTS ME X 21 Set the switches and Jumpers to match the required configuration using the descriptions in this chapter and the strapping guide in the...

Page 9: ...OFF OFF ON ON 192K ON ON OFF ON 128K OFF ON OFF ON 72K ON OFF OFF ON 64K OFF OFF OFF ON 57 6K ON ON ON OFF 56K OFF ON ON OFF 48K ON OFF ON OFF 38 4K OFF OFF ON OFF 28 8K ON ON OFF OFF 19 2K OFF ON OF...

Page 10: ...MANUAL 1 2 0 6 P 1 1 8 0 0 1 U A PATTONELECTRONICSCO SETUP INSTALLATION 2 4 The factory test jumper must be installed for the Modem eliminator to properly function Insure this jumper is installed pri...

Page 11: ...mp 32 to 122 F 0 to 50 C Rel Humidity 5 to 90 non condensing Altitude 0 to 10 000 feet Dimensions Height 1 75 inches 4 44 cm Width 8 90 inches 22 60 cm Length 10 00 inches 25 40 cm DB 15 Connector Pin...

Page 12: ...Kbps HS Option Install Only One Jumper to Select the Required Rate ONLY ON THE OPTIONAL HS VERSION Ch 1 IND Delay SW2 2 ON ON OFF OFF Delay Constant 0 mS 8 mS 50mS Ch 2 IND Delay SW2 5 ON ON OFF OFF D...

Reviews: