Approvals

Safety approvals for UL, CSA & TÜV have been granted allowing the Modem Eliminator to be
used virtually anywhere in the world.  FCC Part 15 class A emissions approvals insure the
Modem Eliminator will not interfere with any of the other equipment in your data center.

CE NOTICE: The CE symbol on your Patton Electronics equipment indicates that it is in
compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage
Directive (LVD) of the Union European (EU).  A Certificate of Compliance is available by
contacting Technical Support.

Available Options

1206P (CTS ME-X.21) is available in both stand-alone subset or rack-mountable versions
(1206PRC).  Various configuration of the interface are also available from the factory.  The
1206PRC fits into the Model 1010R16 16 Card Rack Assembly.

Summary of Contents for 1206P

Page 1: ...MODEM ELIMINATOR X 21 1 2 0 6 P CTS ME X 21 INSTALLATION AND OPERATIONS MANUAL Doc 118001UA Part 07M1206P A Copyright 2000 Patton Electronics Co All Rights Reserved An ISO 9001 CertifiedCompany...

Page 2: ...anty period shall be two years from the date of shipment of equipment Patton s sole obligation under its warranty is limited to the repair or replacement of the defective equipment provided it is retu...

Page 3: ...adiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residentia...

Page 4: ...R 2 SETUP AND INSTALLATION Power Connection 2 1 Factory Configuration Switch Settings 2 1 Disassembly 2 2 Installation 2 2 Equipment Grounding JP4 2 2 IND Delay Port 1 SW2 1 2 2 2 IND Delay Port 2 SW2...

Page 5: ...gh Speed Option are provided by the internal baud rate generator The generator will provide clocks for both terminal and insure the data is synchronized with the S Clock in both directions Delaying IN...

Page 6: ...in your data center CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive L...

Page 7: ...t Factory Configuration Switch Settings The 1206P CTS ME X 21 is configured prior to shipment with the switches set to the followingdefaultpositions Switch 1 2 3 5 and 6 to OFF 1 and 4 to ON Baud Rate...

Page 8: ...uld be used to connect the two terminals to the 1206P CTS ME X 21 Set the switches and Jumpers to match the required configuration using the descriptions in this chapter and the strapping guide in the...

Page 9: ...OFF OFF ON ON 192K ON ON OFF ON 128K OFF ON OFF ON 72K ON OFF OFF ON 64K OFF OFF OFF ON 57 6K ON ON ON OFF 56K OFF ON ON OFF 48K ON OFF ON OFF 38 4K OFF OFF ON OFF 28 8K ON ON OFF OFF 19 2K OFF ON OF...

Page 10: ...MANUAL 1 2 0 6 P 1 1 8 0 0 1 U A PATTONELECTRONICSCO SETUP INSTALLATION 2 4 The factory test jumper must be installed for the Modem eliminator to properly function Insure this jumper is installed pri...

Page 11: ...mp 32 to 122 F 0 to 50 C Rel Humidity 5 to 90 non condensing Altitude 0 to 10 000 feet Dimensions Height 1 75 inches 4 44 cm Width 8 90 inches 22 60 cm Length 10 00 inches 25 40 cm DB 15 Connector Pin...

Page 12: ...Kbps HS Option Install Only One Jumper to Select the Required Rate ONLY ON THE OPTIONAL HS VERSION Ch 1 IND Delay SW2 2 ON ON OFF OFF Delay Constant 0 mS 8 mS 50mS Ch 2 IND Delay SW2 5 ON ON OFF OFF D...

Reviews: