background image

2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected by Patton’s qualified
technicians.  If any questions or problems arise during installation or
use of this product, please do not hesitate to contact Patton Electronics
Technical Support at (301) 975-1007.

2.1  FEATURES

•  Switch-selectable carrier control
•  Field-selectable electrical interfaces, RS-232 and V.35
•  Synchronous or asynchronous operation
•  Data rates of 32, 56 and 64 Kbps
•  Distances to 6 miles 
•  Point-to-point or multipoint 
•  2-wire or 4-wire operation
•  V.54 loopback tests and V.52 compliant BER tests
•  Seven easy-to-read LED indicators
•  Transformer isolation
•  Silicon Avalanche Diode surge protection
•  Switchable 120V or 240V power supply
•  Mounts in Patton’s 16-card rack chassis
•  Made in the U.S.A.

2.2  DESCRIPTION

The Model 1045RC high speed SRM supports sync. and async.

data rates of 32, 56 and 64 Kbps, and distances to 6 miles.  Sync.
transmit clock options are internal, external and receive loopback clock.  

The Model 1045RC incorporates two V.54 test modes: local analog

loop and remote digital loop.  These can be activated from the front
panel, or via the RS-232 or V.35 interface.  Additionally, a built-in V.52
BER test generator can output 511 and 511E bit patterns.  Seven easy-
to-read LED indicators monitor power, transmit data, receive data, RTS,
carrier detect, test mode and test pattern.  For protection against
ground loops and transient surges, the Model 1045 incorporates both
isolation transformers and Silicon Avalanche Diode surge suppressors.

The Model 1045RC is designed to mount in Patton’s 2U high 19”

rack chassis.  This 16-card chassis has a switchable 120/240 VAC
power supply (optional 48 VDC) and mounts cards in a mid-plane
architecture:  The front card can be plugged into different rear cards.
This means that the Model 1045RC card can have several interface
options and can be switched with other Patton short haul cards.

3

3.0  CONFIGURATION

This section describes the location and orientation of the Model

1045RC’s configuration switches and jumpers, and provides detailed
instructions for all possible settings. 

The Model 1045RC uses a combination of DIP switches and

jumpers that allow configuration to an extremely wide range of
applications.  Designed around a mid-plane architecture, the Model
1045RC incorporates both front and rear cards.  Configuration of both
may be necessary.  The switches/jumpers are accessible when the
cards are slid out of the rack chassis.  Once configured, the Model
1045RC is designed to operate transparently, without need for frequent
re-configuration:  just set it and forget it!

3.1  FRONT CARD CONFIGURATION

The Model 1045RC front card has two sets of eight switches (S1 &

S2), one jumper (JP3), and a reversible daughter board, which are all
mounted on the PC board (Figure 1, below).  These configuration
devices allow you to select data rates, clocking methods, V.52 & V.54
tests, word lengths, extended signaling rates, async. or sync. mode,
2- or 4-wire operation, and RS-232 or V.35 terminal interface.  The
ON/OFF orientation of the DIP switches  is shown in figure 2 (above). 

4

1

2

3

4

5

6

7

8

ON

OFF

ON

Figure 2. Close-up of DIP switches showing “ON” and “OFF” positions

Figure 1. Model 1045RC board, showing location of switches/jumper 

S1

S2

JP3

daughter
board

Summary of Contents for 1045RC

Page 1: ...Powered High Speed Short Range Modem Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1045RC B Doc 054051UB Revised 3 14 97 C E R T I F I E D An IS...

Page 2: ...ar installation If the Model 1045RC does cause interference to radio or television reception which can be determined by turning the power off or removing the card the user is encouraged to try to corr...

Page 3: ...iode surge suppressors The Model 1045RC is designed to mount in Patton s 2U high 19 rack chassis This 16 card chassis has a switchable 120 240 VAC power supply optional 48 VDC and mounts cards in a mi...

Page 4: ...peration in switched carrier multipoint and or hardware handshaking applications S1 7 Setting Off Constantly on On Controlled by RTS S1 8 V 52 and V 54 Diagnostic Test To reset the V 54 circuit set sw...

Page 5: ...ng mode S2 6 Setting On Asynchronous Off Synchronous Note in asynchronous mode the Clock Source must be set to Internal S1 5 On S1 6 On 7 S2 7 RS 232 V 35 Initiation of Local Analog Loopback Test The...

Page 6: ...ward the front of the PC board 9 3 2 REAR CARD CONFIGURATION The Model 1045RC has four rear interface card options DB 25 RJ 11 DB 25 RJ 45 M 34 RJ 11 and M 34 RJ 45 see Figure 5 below Each of these op...

Page 7: ...ignal Ground and frame ground In the open position pin 1 or pin B is lifted from frame ground JB4 Position 1 2 SGND DB 25 pin 7 or M 34 pin B and FRGND Connected Position 2 3 SGND DB 25 pin 7 or M 34...

Page 8: ...lled cards 4 2 INSTALLING THE MODEL 1045RC INTO THE CHASSIS The Model 1045RC is comprised of a front card and a rear card The two cards meet inside the rack chassis and plug into each other by way of...

Page 9: ...ment are NOT acceptable For further information about acceptable wire grades please refer to the diagram in appendix B Point to Point Twisted Pair Connection The 6 position RJ 11 and 8 position RJ 45...

Page 10: ...LED will blink sporadically 17 4 If the BER test indicates no errors are present move the V 52 toggle switch to the left thus activating the 511 E test with periodic errors If the test is working pro...

Page 11: ...ch on both Model 1045RCs must be turned on 2 If the test indicates no errors are present move the V 52 toggle switch to the left thus activating the 511 E test with errors present If the test is worki...

Page 12: ...he above data rate distance table as a general guideline only 21 APPENDIX C MODEL 1045RC FACTORY REPLACEMENT PARTS The Patton Model 1045RC rack system features interchangeable rear cards power cords f...

Page 13: ...m 1045RC 9 Receive Clock B From 1045RC 11 External Clock B To 1045RC 12 Transmit Clock B From 1045RC To 1045RC Data Term Ready DTR 20 DIRECTION CCITT V 35 EIA 530 INTERFACE DB 25 DIRECTION To 1045RC E...