3.2.1 SWITCH SETTINGS
All possible settings for the Model 1004’s configuration switches
are presented in the summary table below. If you have additional
questions, contact Technical Support at (301) 975-1000.
SW 1-1: RTS/CTS Delay
The setting for Switch SW1-1 determines the amount of delay
between the time the Model 1004 “sees” RTS and when it sends CTS.
(This option is available in DCE mode only).
SW1-1
Setting
Off
0mS
On
8mS
SW 1-2: Echo Enable
Switch SW1-2 determines whether the Model 1004 echoes data
back to the transmitting device. (Half duplex modes only).
SW1-2
Setting
Off
Echo Off
On
Echo On
SW 1-3: Carrier Control Method
Switch SW1-3 determines whether the carrier is “constantly on” or
“controlled by RTS”. This setting allows for operation in switched carri-
er, multipoint and/or hardware handshaking applications.
SW1-3
Setting
Off
Constantly “on”
On
Controlled by RTS
5
SWITCH SUMMARY TABLE
Position
Function
Off Position
On Position
SW1-1
RTS/CTS Delay
0mS
8mS
SW1-2
Echo Enable
Echo “Off”
Echo “On”
SW1-3
Carrier Control
Constantly “On”
Controlled by RTS
SW1-4
Impedance
High (120K Ohm)
Low (120 Ohm)
SW2
2 wire/4 wire
2-wire
4-wire
SW 1-4: Impedance
Switch SW1-4 defines a termination resistance. The Model 1004’s
generator can drive 50 unit loads including two termination resistances
of 120 Ohms each.
SW1-4
Setting
Off
High (120K Ohm)
On
Low (120 Ohm)
SW 2: 2-Wire/4-Wire
Switch SW1-4 determines whether the Model 1004 will operate in
either 2-wire or 4-wire mode.
SW1-4
Setting
Off
2-wire
On
4-wire
3.2.2 CONFIGURATION SWITCH APPLICATIONS
The table below shows you how to set the Model 1004's configu-
ration switches to fit several common applications. If you have any
questions, call Patton Technical Support at (301) 975-1007.
*NOTE: RTS/CTS Delay setting should be based upon transmission timing.
6
SW1-1: RTS/CTS*
ON
ON
ON
ON
ON
SW1-2: Echo
OFF
ON
OFF
ON
OFF
SW1-3: Carrier
OFF
ON
ON
Master-OFF
ON
Slaves-ON
SW1-4: Impedance
ON
ON
ON
Master - ON
Slaves - HIGH
Last Slave - ON
SW2: 2-wire/4-wire
ON
ON
OFF
ON
OFF
TYPICAL SWITCH APPLICATIONS
Point-to-Point
Switch
Settings
Multi-point
4W
2W
4W
2W
4W HDX
Summary of Contents for 1004