RJ-45 Cable (4-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

GND

2-----------------------7

GND

RCV-

3-----------------------5

XMT-

XMT+

4-----------------------6

RCV+

XMT-

5-----------------------3

RCV-

RCV+

6-----------------------4

XMT+

GND

7-----------------------2

GND

RJ-11 Cable (2-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

XMT+

3-----------------------3

XMT+

XMT-

4-----------------------4

XMT-

RJ-45 Cable (2-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

XMT+

4-----------------------4

XMT+

XMT-

5-----------------------5

XMT-

Connection to ground is optional

4.2  WIRING FOR MULTIPOINT CIRCUITS

The Model 1004 supports multi-point applications using either a

star or daisy chain topology.  Both topologies require special wiring, as
well as specific DIP switch settings for master and slave units.  Note:
Refer to Section 3.2.2 for multipoint DIP switch settings.

4.2.1  STAR TOPOLOGY

Using a star topology, you may connect several Model 1004s

together in a master/slave arrangement.  Maximum distance between
the units will vary based upon the number of drops, data rate, wire
gauge, etc.  Call Technical Support for specific distance estimates.

12

4.1.2  TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45

The RJ-11 and RJ-45 connectors on the Model 1004’s twisted pair

interface are pre-wired for a standard TELCO wiring environment.  The
signal/pin relationships are shown below:

RJ-11

SIGNAL

RJ-45

SIGNAL

1 ...................GND

1 ...................N/C

2 ...................RCV-

2 ...................GND

3 ...................XMT+

3 ...................RCV-

4 ...................XMT-

4 ...................XMT+

5 ...................RCV+

5 ...................XMT-

6 ...................GND

6 ...................RCV+
7 ...................GND
8 ...................N/C

Connection to ground is optional

AT&T standard modular color codes

When connecting two Model 1004’s, it is necessary to use a

crossover cable.  The diagrams below show how a crossover cable
should be constructed for the following environments:  4-wire RJ-11,
4-wire RJ-45, 2-wire RJ-11 or 2-wire RJ-45.

RJ-11 Cable (4-Wire)

SIGNAL

PIN#

PIN#

SIGNAL

GND

1-----------------------6

GND

RCV-

2-----------------------4

XMT-

XMT+

3-----------------------5

RCV+

XMT-

4-----------------------2

RCV-

RCV+

5-----------------------3

XMT+

GND

6-----------------------1

GND

Connection to ground is optional

11













Summary of Contents for 1004

Page 1: ...USER MANUAL SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1004 C Doc 047011UC Revised 8 10 95 MODEL 1004 and 1004S High Speed Multipoint Short Range Modem...

Page 2: ...be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Pa...

Page 3: ...t ting causes the Model 1004 to behave like Data Communications Equipment and transmit data on pin 3 3 DCE DTE DCE DTE Switch 2 Wire 4 Wire Switch Surge Suppressors 1004S only Terminal Block Control S...

Page 4: ...RTS CTS Delay 0mS 8mS SW1 2 Echo Enable Echo Off Echo On SW1 3 Carrier Control Constantly On Controlled by RTS SW1 4 Impedance High 120K Ohm Low 120 Ohm SW2 2 wire 4 wire 2 wire 4 wire SW 1 4 Impedanc...

Page 5: ...quires you to connect one or two pairs of bare wires to the Model 1004 you will need to open the case to access the terminal blocks The following instructions will tell you how to open the case connec...

Page 6: ...act our technical support We have strain relief assemblies to accommodate most cable diameters RCV G XMT RCV G XMT 9 10 Insert the strain relief assembly and wire into the slot in the bottom half of t...

Page 7: ...ll vary based upon the number of drops data rate wire gauge etc Call Technical Support for specific distance estimates 12 4 1 2 TWISTED PAIR CONNECTION USING RJ 11 OR RJ 45 The RJ 11 and RJ 45 connect...

Page 8: ...Figure 5 Daisy chain wiring for Model 1004 host and slaves With the dual modular units you won t need to build cumbersome Y cables for your daisy chain application Simply use a crossover cable to go...

Page 9: ...r No external power required uses ultra low power from EIA data and control signals Size 2 66 x 2 10 x 0 73 15 APPENDIX B RS 232 PIN CONFIGURATIONS 1 FG Frame Ground 2 TD Transmit Data To Model 1004 3...

Page 10: ...APPENDIX C BLOCK DIAGRAM 17...

Reviews: