8.
Replace the spare fuse with one of the appropriate size and rating
and close the drawer.
9.
Re-install the power cord.
(Step #6- 9 for Model 1000RPEM-V)
6.
Using a small screwdriver, push in lightly and turn counter
clockwise to open the compartment. The top will pop open with the
fuse attached.
7.
If the active fuse appears to be blown, remove it from the front
container. Note the size and rating of the blown fuse before
discarding (*120V = TO.4; 240V = TO.2).
8.
Replace the spare fuse with one of the appropriate size and rating
and close the compartment.
9.
Re-install the power cord.
APPENDIX A
SPECIFICATIONS
1000RPSM-2 and 1000RPSM-V (AC Front Cards):
Power Supply: 120V AC or 220-24V AC, switchable
Input Voltage: “120V AC” setting: 100-130V AC; “220V AC” setting:
200-240V AC
Maximum Input Current: “120V AC” setting: 400mA; “220V AC”
setting: 200mA
Isolation Voltage: Model 1000RPSM-2: 1.5 kV AC;
Model 1000RPSM-V: 5 kV AC
Output Voltage: 10V AC @ 2.4 A
Output Power: 24VA
Switches: Power on/off
LED Indicator: Power
1000RPEM and 1000RPEM-V (AC Rear Cards):
Connection: IEC-320 Shrouded Male
Fuse: 120V AC: 5x20mm, 400mA, Time-Delay; 240V AC: 5x20mm,
200mA, Time-Delay
WARNING!
Replace the fuse only with one that has
the correct voltage and current rating for the voltage
setting of the unit (the proper fuse ratings will be marked
on the rear panel of the unit*). Replacing the fuse with
one having an incorrect rating can result in a fire!