Front (Power Supply) Card Installation

1.

Make sure the power switch is in the OFF position.

2.

Slide the power supply card into the front of the chassis.  It should
meet the rear card when it's almost all the way into the chassis.

3.

Push the front card gently into the multipin connector on the
rear card.  

4.

Secure the front card using the thumb screws.

3.3  REAR CARD POWER CONNECTION - AC VERSIONS

The Model 1000RPEM and 1000RPEM-V rear cards are equipped

with a shrouded male IEC-320 AC power interface.  This interface
accepts a domestic US power cord (supplied) or any number of
international power cords (see Appendix B).

3.4  REAR CARD POWER CONNECTION - DC VERSION

The Model 1000RPEM-DC rear card comes equipped with a cage

clamp terminal block.  The following instructions will tell you how to
install the rear card.

1.

Strip back the insulation on each of the wires .25”.

(continued)

3.0  INSTALLATION

Patton’s Model 1000RP Series power supply modules are easy to

install and require no configuration.  This section describes the
functions of the Model 1000R16P rack chassis, tells how to install front
and rear power supply cards into the chassis and how to make the
power interface connections.

3.1  THE MODEL 1000R16P RACK CHASSIS

The Model 1000R16P Rack Chassis (Figure 1, below) features

sixteen function card slots and one power supply card slot.  (Note: refer
to function card user manuals for proper installation of function cards)
Measuring only 3.5” high, the Model 1000R16P is designed to occupy
only 2U in a 19” rack.  Sturdy front handles allow the Model 1000R16P
to be extracted and transported conveniently.

3.2  INSTALLING POWER SUPPLY MODULES

All power supply modules (AC or DC) are comprised of two cards:

the front power supply card and the rear power entry card.  These two
cards meet inside the rack chassis and plug into each other by means
of a multipin connector.  (The same holds true for all Patton Cluster
Boxes as well.)  Use the following steps as a guideline for installing
each power supply module into the Model 1000R16P rack chassis:

Rear (Power Entry) Card Installation

1.

Attach the ground wire using the star washer and the #6-32 nut.
Use a wrench to tighten the nut securely.

2.

Slide the power entry card into the back of the chassis along the
metal guide rails provided.

3.

Secure the rear card using the #4-40 metal screws provided.

3

4

Figure 1. Model 1000R16P Rack Chassis with Power Supply 

Caution:

To avoid shock hazard, do not connect AC

or DC power cable(s) until power supply module is fully
assembled.

Caution:

Connect the equipment to a SELV DC

supply source that is electrically isolated from the AC
power sources.  The DC power source should also be
reliably connected to earth ground.

Summary of Contents for 1000RP Series

Page 1: ...USER MANUAL Model 1000RP Series AC and DC Rack Mount Power Supplies SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1000RP B Doc 078011UB Revised 3 19 96...

Page 2: ...on the outside of the shipping container This number may be obtained from Patton Electronics Technical Service at 301 975 1007 Packages received without an RMA number will not be accepted Patton s te...

Page 3: ...Chassis Figure 1 below features sixteen function card slots and one power supply card slot Note refer to function card user manuals for proper installation of function cards Measuring only 3 5 high th...

Page 4: ...wer switch is turned on and low voltage AC power is available to the function cards installed in the rack The DC Input LED will light whenever a power source is present with correct polarity regardles...

Page 5: ...OFF 2 Remove the power plug from the AC wall outlet 3 Remove the power plug out of the rear of the unit 4 Switch the unit ON and verify that the front panel Power LED is not lit Switch the unit OFF 5...

Page 6: ...1000RPSM 2 and 1000RPSM V AC Front Cards Power Supply 120V AC or 220 24V AC switchable Input Voltage 120V AC setting 100 130V AC 220V AC setting 200 240V AC Maximum Input Current 120V AC setting 400mA...

Page 7: ...d Connection Cage clamp terminal block with DC In DC In Frame Ground Alarm Alarm C DC Out DC Out Wire 26 14 solid or stranded cable Alarm Opens when power is attached and closes when power is disconne...

Reviews: