background image

1.0  WARRANTY INFORMATION 

Patton Electronics warrants all Model 1000CC components to be

free from defects, and will—at our option—repair or replace the product
should it fail within one year from the first date of shipment.

This warranty is limited to defects in workmanship or materials, and

does not cover customer damage, abuse or unauthorized modification.
If this product fails or does not perform as warranted, your sole
recourse shall be repair or replacement as described above.  Under no
condition shall Patton Electronics be liable for any damages incurred
by the use of this product.  These damages include, but are not limited
to, the following:  lost profits, lost savings and incidental or
consequential damages arising from the use of or inability to use this
product.  Patton Electronics specifically disclaims all other warranties,
expressed or implied, and the installation or use of this product shall be
deemed an acceptance of these terms by the user. 

1.1  RADIO AND TV INTERFERENCE

The Model 1000CC generates and uses radio frequency energy,

and if not installed and used properly—that is, in strict accordance with
the manufacturer's instructions—may cause interference to radio and
television reception.  The Model 1000CC has been tested and found to
comply with the limits for a Class A computing device in accordance
with the specifications in Subpart J of Part 15 of FCC rules, which are
designed to provide reasonable protection from such interference in a
commercial installation.  However, there is no guarantee that
interference will not occur in a particular installation.  If the Model
1000CC does cause interference to radio or television reception, which
can be determined by turning the power off or disconnecting the
RS-232 interface, the user is encouraged to try to correct the
interference by one of the following measures:  moving the computing
equipment away from the receiver, re-orienting the receiving antenna
and/or plugging the receiving equipment into a different AC outlet (such
that the computing equipment and receiver are on different branches).

1.2  SERVICE

All warranty and non-warranty repairs must be returned freight

prepaid and insured to Patton Electronics.  All returns must have a
Return Materials Authorization number on the outside of the shipping
container.  This number may be obtained from Patton Electronics
Technical Service at (301) 975-1007.  

Packages received without an

RMA number will not be accepted.

Patton Electronics' technical staff is also available to answer any

questions that might arise concerning the installation or use of your
Model 1000CC.  Technical Service hours:  8AM to 5PM EST, Monday
through Friday.

1

2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Technical Support at (301) 975-1007.

2.1  FEATURES

• Lets an async RS-232 terminal configure or dial Patton’s

2500RC Series of CSU/DSU rack cards 

• Fits in Patton’s rack chassis and Cluster Boxes 

• Supports RS-232 terminal data rates to 19.2 Kbps

• Daisy chain capability lets one terminal control many racks

• Works in conjunction with Patton short range modem rack cards to

provide remote daisy chain option

2.2  DESCRIPTION

The Model 1000CC RS-232 Rack Mount Controller Card  fits in

Patton’s rack chassis and Cluster Boxes and allows the 2500RC family
of CSU/DSUs to be configured and controlled from an asynchronous
RS-232 terminal.  Taking up one card slot, the Model 1000CC provides
one modular port for connection of an RS-232 terminal, and a second
modular port for daisy-chaining between racks.  The user wishing to
“dial” or configure a particular CSU/DSU card simply keys in an
addressable command, which the Model 1000CC passes along to all
the cards in the rack.  The appropriate card recognizes its address and
responds to the command.    

Daisy-chaining with one or more other racks containing a Model

1000CC can be done locally or remotely.  To accomplish remote daisy-
chaining,  the daisy-chain port of a Model 1000CC is connected to a
Patton short range modem card.  The terminal link is then driven to a
remote rack with a second short haul and a  Model 1000CC.
Combining local and remote daisy chaining, a single RS-232 terminal
can control a whole network of Patton CSU/DSUs.  The Model 1000CC
has front panel LED indicators for Power, TD and RD.  A special rear
card, the Model 1000RCM1C45, is supplied with the unit.  Other rear
cards are also compatible with the Model 1000CC. 

2

Summary of Contents for 1000CC

Page 1: ...USER MANUAL MODEL 1000CC RS 232 Rack Mount Controller Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1000CC A Doc 022010UA Revised 9 22 95...

Page 2: ...n Materials Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Service at 301 975 1007 Packages received without an RMA number...

Page 3: ...proper operation if the jumper is installed incorrectly JB6 JB7 Position 1 2 DSR Position 2 3 N A 4 3 0 CONFIGURATION The Model 1000CC has no configuration straps or switches except those associated w...

Page 4: ...itch may be 110 220 or 115 230 2 Replace the existing fuse with one of the correct value see Appendix C for the appropriate fuse 3 Replace the power supply cord if necessary see Appendix C for the app...

Page 5: ...ps demonstrate the installation of the Model 1000CC into the chassis 1 Slide the rear card into the back of the chassis along the metal rails 2 Secure the rear card using the metal screws provided 3 S...

Page 6: ...power up procedure and use of the Model 1000CC 5 1 LED STATUS MONITORS The Model 1000CC features five front panel LEDs that indicate the condition of the modem and communication link These LEDs opera...

Page 7: ...try Module 1000RPSM 1 120 240V Front Power Supply Module 1000RPEM DC DC Rear Power Entry Module 1000RPSM 48A 48V Front Power Supply Module 12M 561 Serial DB 25 male to RJ 45 adapter 12F 561 Serial DB...

Page 8: ...N A Not Used 2 107 DSR 3 109 Received Line Signal Indicator CD 4 108 2 DTE Ready DTR 5 102 Signal Common 6 104 Received Data 7 103 Transmitted Data 8 106 Clear to Send 9 105 133 Request to Send Ready...

Reviews: