GB
- 240 -
Power supply
The lawn mower can be connected to any light socket-outlet with
a 220-240 Volt alternating current. However, the socket outlet must
have an earthing contact protected by a 16 A circuit breaker. Additio-
nally, a residual current device (RCD) circuit-breaker with max. 30 mA
must be used!
Power cable for the device
Please only use power cables that are not damaged. The total length
of the power cable should not exceed 50 meters; going beyond this
distance will reduce the power output of the electric motor. The power
cable must have a cross-section of 3 x 1.5 mm. The insulating sheath
of lawn aerator power cables is frequently damaged.
Some of the causes for this are:
•
Cuts caused by driving over the cable.
•
Pinching when the power cable is dragged under doors and
pulled through windows.
•
Cracking due to old age of the insulation.
•
Kinking by improperly fastening or guiding the power cable.
The power cables must, at the very minimum, be of type HO5RN-F
and 3-stranded. The cable type must be printed somewhere on the
power cable. Only purchase power cables that are marked! Plugs
and socket couplers for the power cables must be made from rubber
and splash-proof. There is a limit to how long power cables can be.
Longer power cables require larger conductor cross-sections. Power
cables and connecting lines must be regularly checked for damage.
Ensure that the lines are switched o
ff
before checking them. Com-
pletely unwind the power cable. Also check power cable entry points,
plugs and socket couplers for kinks.
Anl_PE_EM_1536_SPK7.indb 240
Anl_PE_EM_1536_SPK7.indb 240
26.08.15 09:17
26.08.15 09:17
Summary of Contents for 5599906
Page 255: ...255 Anl_PE_EM_1536_SPK7 indb 255 Anl_PE_EM_1536_SPK7 indb 255 26 08 15 09 17 26 08 15 09 17...
Page 256: ...256 Anl_PE_EM_1536_SPK7 indb 256 Anl_PE_EM_1536_SPK7 indb 256 26 08 15 09 17 26 08 15 09 17...
Page 257: ...257 Anl_PE_EM_1536_SPK7 indb 257 Anl_PE_EM_1536_SPK7 indb 257 26 08 15 09 17 26 08 15 09 17...