background image

3

 

Patron E9 - 12/00 

1.     GENERAL INFORMATION FOR USER

 

 

Patron electric heaters are designed for professional use.  
 
The heat is generated in sealed heating elements inside the inner mantle of the 
heater. Heated air is then distributed by an electric motor driven fan blowing air 
through the heater. 
 
Although effectively cooled by the fan, the heating elements have high surface tem-
peratures. That is why combustible materials must be kept at a safe distance from 
the heater and care must be taken that no combustible particles enter the heater 
with the air sucked in by the fan. 
 
Keep the heater clean of dust at any time. Dust may cause fire when heated. 
 
Make sure that the fan blades may rotate unobstructed at all times. 
 
Do not block air intakes or exhaust in any manner. 
 
 

2.     LIMITED WARRANTY 

 

PATRON heater products are professional construction heaters. They are warranted for 
twenty-four (24) months from original date of purchase. The warranty does not cover 
products modified outside our factory, damage or failure caused by acts of God, abuse, 
misuse, use on other than rated voltage, abnormal usage, faulty or improper installation, 
failure to provide recommended maintenance or any repairs other than those provided by 
an authorized PATRON service. 
 
THERE ARE NO OBLIGATIONS OR LIABILITIES ON THE PART OF PATRON PROD-
UCTS INC. FOR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION 
WITH THE USE OR PERFORMANCE OF THE PRODUCT OR OTHER INDIRECT 
DAMAGES WITH RESPECT TO LOSS OF PROPERTY, REVENUES, OR PROFIT, OR 
COST OF REMOVAL, INSTALLATION OR REINSTALLATION. 
 
THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PURCHASER 
OF EQUIPMENT SOLD BY THE MANUFACTURER AND ITS DEALERS AND DISTRIBU-
TORS AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. 
 
During the warranty period, Patron Products will, at its sole option, repair or replace any 
defective parts or products returned, freight prepaid, to Patron Products or such other lo-
cation as Patron Products may designate. 
 
Returned products must be packaged carefully, and Patron Products shall not be respon-
sible for damage in transit. When returning parts, the owner must provide the model num-
ber of the product and the nature of difficulty being experienced. This warranty does not 
oblige Patron Products to bear the cost of labour in replacing any assembly, unit or com-
ponent or part thereof, nor does the company assume any liability for secondary charges, 
expenses of removal or installing, freight or damages. There will be charges rendered for 
product repair after our warranty period has expired. Proof of purchase, including date, 
must accompany request for in-warranty service. 

 
 

Summary of Contents for PATRON E9

Page 1: ...ATRON E9 ELECTRIC FAN HEATER 12 00 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE ASSEMBLING STARTING OR SERVICING THE HEATER IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY KEEP THIS MANUAL FOR FUTURE REFERENCE FOR PROFESSIONAL USE ONLY ...

Page 2: ...r liquid container 7 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped over 8 To disconnect heater turn controls to off then remove plug from outlet 9 Connect to properly grounded outlets only 10 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may caus...

Page 3: ...n authorized PATRON service THERE ARE NO OBLIGATIONS OR LIABILITIES ON THE PART OF PATRON PROD UCTS INC FOR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCT OR OTHER INDIRECT DAMAGES WITH RESPECT TO LOSS OF PROPERTY REVENUES OR PROFIT OR COST OF REMOVAL INSTALLATION OR REINSTALLATION THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PURCHASER OF ...

Page 4: ...ect amperage rating 3 Turn the toggle switch into position on and the fan starts 4 Set the room thermostat to a temperature above the ambient room temperature by turning the knob Note The heater will heat up only if the thermostat calls for heat meaning that it is set to higher than prevailing ambient temperature 5 The heater will now operate automatically controlled by the thermostats TO STOP HEA...

Page 5: ...s sealed and has permanently lubricated bearings 5 STORAGE When not in use the heater must be disconnected from power source cleaned of dust and stored in a dry place The power supply cord should be loosely wound around the handle of the heater 6 TECHNICAL SPECIFICATIONS MODEL PATRON E9 Heat output BTU hr 30 700 9 000 W Air flow CFM 350 600 m h Electric connection V ac Hz 240 60 single phase Amper...

Page 6: ...heminee interieure 4008005 6 handle poignee 80100 7 heating element 3 pcs element 3 pcs 42800 8 fan motor motor du ventilateur 14201 9 fan blade pales du ventilateur 16110 10 contactor contacteurs 22570 11 room thermostat knob thermostat ambiant 20210 20575 12 toggle switch interrupteur 26900 13 strain reliever retenue de fil 36930 14 overheat limit switch disjoncteur de surchauffe 21200 hub for f...

Page 7: ...14201 R1 3 heating element element 42800 S1 toggle switch interrupteur 26900 S2 room thermostat thermostat ambiant 20210 S3 overheat limit switch disjoncteur de surchauffe 21200 X1 terminal block bloc terminal 36703 X2 grounding lug bloc terre X3 power cord plug fil electrique fiche t 8 WIRING DIAGRAM ...

Page 8: ...8 Patron E9 12 00 PATRON PRODUCTS INC USA 60 Clyde Avenue Suite 4 Buffalo NY 14215 Canada 12 110 Ironside Crescent Scarborough Ontario M1X 1M2 ...