![background image](http://html1.mh-extra.com/html/patron/gi-3500p/gi-3500p_user-manual_4016291021.webp)
21
6.3 Alternating Current (AC) connection
WARNING
• Be sure any electric devices are turned off before plugging them in.
NOTICE
• Be sure all electric devices including the lines and plug connections
are in good condition before connection to the generator.
• Be sure the total load is within the generator’s rated output.
• Be sure the receptacle load current is within receptacle rated current.
• The generator (STATOR WINDING) is isolated from the AC
receptacle ground pin.
• Electrical devices that require a grounded receptacle pin connection
will not function if the receptacle ground pin is not functional.
TIP:
Make sure to ground the generator. When the electrical device is
grounded, the generator must also be grounded.
1. Start the engine.
2. Turn the ESC to “ON”.
3. Plug in to AC receptacle.
4. Make sure the AC pilot light is on.
5. Turn on any electric devices.
TIP:
The ESC must be turned to “OFF” to increase engine speed to rated
rpm. If the generator is connected to multiple loads, please remember to
connect the one with the highest starting current first and connect the
one with the lowest starting current last.
6.4 Battery Charging
TIP:
• The generator DC rated voltage is 12V.
• Start the engine first, and then connect the generator to the battery for
charging.
• Before starting to charge the battery, make sure that the DC protector is
turned on.
1. Start the engine.
2. Connect the red battery charger lead to the positive (+) battery
terminal.
3. Connect the black battery charger lead to the negative (-) battery
terminal.
4. Turn the ESC “off” to start battery charging.