Safety disarming setting
At the completely connection END, it’s necessary to memor
ize the original deactivate immobilizer
sequence, reading the confirm by the
“LED Immobilizer”
flashing. In this way, the alarm disarming, depends
not only by the turn ON ignition
key, but also by the original unlock sequence that you can see on the “LED
Immobilizer” flashing.
To make the programme, you must follow this procedure:
▪
Connect the WHITE and BLACK connector of the alarm to the HPS 430;
▪
The alarm LED flashes for 15 seconds and, into this time, you must turn ON and turn OFF the
ignition key 4 times. The LED fixed ON and a beep confirms the procedure start;
▪
Turn On the ignition key, a beep series confirms the control and an acoustical signal indicates the
“LED Immobilizer”
flashing end. The LED of the alarm will repeat the original unlock sequence
memory and, trough the acoustical signal, confirms the procedure end.
ATTENTION: if you want that this procedure will be memorized
, it’s necessary to turn ON the button
“RUN” of the motorcycle.
If this button is turned
OFF, when you turn ON the ignition key, the “LED
Immobilizer” will not signal the original unlock sequence trough the flashing.
Reading LED exclusion:
It’s
possible, for the vehicles that have not the Immobilizer system, to exclude this condition. If you
compose the code 21, the alarm deactivation
will be without the reading “LED Immobilizer”
.
This is the original condition before the programme.
It’s possibl
e to restore the reading if you make again
the previous procedure.
LED immobilizer TEST
To verif
y the correct “LED Immobilizer” connection it’s possible to activ
ate a temporary reading function:
If you compose the N° 19 code you’ll active the TEST LED procedure, when
the LED is ON the alarm gives an
acoustical signal that indicates the correct reading. To stop the procedure,
it’s necessary to turn OFF the
ignition key.
CONN
E
S
S
IONE
L
E
D IM
M
OB
IL
IZ
E
R
(OPZIO
NA
L